Bryant EVOLUTION 187B Product Data

Bryant EVOLUTION 187B Product Data

17 air conditioner with puron refrigerant
Hide thumbs Also See for EVOLUTION 187B:

Advertisement

187B (2 - - 5 Ton)
180B (3 Ton Trophy)
EVOLUTIONt 17 AIR CONDITIONER
WITH PURONr REFRIGERANT
the environmentally sound refrigerant
Bryant's air conditioners with Puron r refrigerant provide a
collection of features unmatched by any other family of
equipment. The 187B and 180B have been designed utilizing
Bryant's Puron r refrigerant. The environmentally sound
refrigerant allows consumers to make a responsible decision in
the protection of the earth's ozone layer.
As an Energy Starr Partner, Bryant Heating & Cooling Systems
has determined that this product meets the Energy Star r
guidelines for energy efficiency. Refer to the combination ratings
in the Product Data for system combinations that meet Energy
Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
Comfort
S
Reliability
S
TM
S
S
S
S
S
S
S
S
Durability
DuraGuardt protection package:
S
S
S
Applications
S
14 - - 20 SEER / 11.6 - - 14.5 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 71 dBA
System supports Evolutiont Control or standard
2- -stage thermostat controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime service cost.
Front- -seating service valves
2- -stage scroll compressor
Internal pressure relief valve
Internal thermal overload
Low pressure switch
High pressure switch
Filter drier
Balanced refrigeration system for maximum reliability
Solid, Durable sheet metal construction
Steel louver coil guard
Baked- -on, complete outer coverage, powder paint
Long- -line - - up to 250 feet (76.2 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)

Advertisement

Table of Contents
loading

Summary of Contents for Bryant EVOLUTION 187B

  • Page 1: Product Data

    Filter drier the protection of the earth’s ozone layer. Balanced refrigeration system for maximum reliability As an Energy Starr Partner, Bryant Heating & Cooling Systems Durability has determined that this product meets the Energy Star r guidelines for energy efficiency. Refer to the combination ratings...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Minor Family Series Series 1=AC 7, 0 =17 B=Puron 0=Not Evolution SEER Standard Defined Original 208--- 230--- 1 Series Nominal Defined Defined Series ISO 9001:2000 the environmentally sound refrigerant REGISTERED Use of the AHRI Certified TM Mark indicates a...
  • Page 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
  • Page 4: Physical Data

    LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
  • Page 5: Electrical Data

    ELECTRICAL DATA OPER FUSE* UNIT COMPR WIRE WIRE LENGTH LENGTH VOLTS* * or SIZE --- SIZE{ SIZE{ ft (m)} ft (m)} MODEL V--- PH --- Hz SERIES 60°C 75°C 60°C 75°C AMPS 024--- A 208/230 ---1 ---60 52.0 10.30 13.6 14.00 14.00 60 (18.3)
  • Page 6 ACCESSORIES KIT NUMBER KIT NAME 024--- A 036--- A 048--- A 060--- A KSAHS2301AAA HARD START KIT KSAHS2401AAA HARD START KIT KSAHS2501AAA HARD START KIT KSAHS2601AAA HARD START KIT KSASF0101AAA SUPPORT FEET KSATX0201PUR KSATX0301PUR KSATX0401PUR KSATX0501PUR x = Accessory CONTROLS CONTRIL DESCRIPTION SYSTXBBUID01--- B*...
  • Page 7 Required when low ambient kit has been added. operation. 4. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 12 Wall...
  • Page 13 COMBINATION RATINGS Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747088 187BNA024****A †CNPV*4217A** 313*AV024045 25,200 21,000 13.2 16.0 3747089 187BNA024****A CAP**2414A**+TDR 24,200 20,000 11.8 14.0 3747187 187BNA024****A CAP**2417A** 353AAV036040 25,200 21,200 13.3 16.5 3747200...
  • Page 14: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747147 187BNA024****A CNPH*3617A**+UI 355AAV042040 24,800 20,400 13.1 16.0 3747112 187BNA024****A CNPV*2414A** 313*AV024045 24,600 20,600 12.9 16.0 3747110 187BNA024****A CNPV*2414A**+TDR 24,200 20,200 11.8 14.0...
  • Page 15 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747177 187BNA024****A CSPH*3612A** 313*AV024045 25,400 21,200 13.3 16.5 3747198 187BNA024****A CSPH*3612A** 353AAV036040 25,800 21,800 13.7 17.0 3747178 187BNA024****A CSPH*3612A** 359BAV036040 25,600 21,000 13.1...
  • Page 16 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747238 187BNA036****A CAP**4817A**+UI 355(A,C)AV042060 37,200 30,000 13.0 17.0 1055 3747484 187BNA036****A CAP**4817A**+UI 355BAV042060 37,200 30,000 13.0 17.0 1055 3747373 187BNA036****A CAP**4821A** 368RAN036105 36,800...
  • Page 17 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747256 187BNA036****A CNPV*3621A**+UI 315(A,J)AV060110 35,800 29,000 12.7 16.5 1020 3747253 187BNA036****A CNPV*3621A**+UI 355(A,C)AV042080 35,600 29,000 12.4 16.0 1030 3747254 187BNA036****A CNPV*3621A**+UI 355(A,C)AV060080 35,600...
  • Page 18 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747320 187BNA036****A CSPH*3612A**+UI 315(A,J)AV048090 36,600 29,600 13.0 16.5 1005 3747321 187BNA036****A CSPH*3612A**+UI 315(A,J)AV060110 36,600 29,600 13.0 16.5 1020 3747322 187BNA036****A CSPH*3612A**+UI 315(A,J)AV066135 36,600...
  • Page 19 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3748021 180BNA036****A CNPH*3617A** 353(A,B)AV036080 36,400 30,400 13.3 18.0 1035 3748022 180BNA036****A CNPH*3617A** 353(A,B)AV048080 36,600 30,400 13.0 18.0 1055 3748050 180BNA036****A CNPH*3617A** 359BAV060080 36,400...
  • Page 20 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747940 180BNA036****A CNPV*3621A**+UI 355(A,C)AV042060 36,400 30,000 13.3 18.0 1055 3747941 180BNA036****A CNPV*3621A**+UI 355(A,C)AV042080 36,200 29,600 13.1 18.0 1030 3747942 180BNA036****A CNPV*3621A**+UI 355(A,C)AV060080 36,200...
  • Page 21 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3748071 180BNA036****A CNPV*4821A** 368RAN036105 37,200 28,000 13.5 18.0 1065 3748073 180BNA036****A CNPV*4821A** 368RAN060120 38,000 31,000 14.0 20.0 1005 3748070 180BNA036****A CNPV*4821A** 374RAN036105 37,400...
  • Page 22 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3748046 180BNA036****A CSPH*4812A** 313*AV048090 38,000 31,600 13.8 19.0 1070 3748047 180BNA036****A CSPH*4812A** 353(A,B)AV036060 37,800 31,400 13.9 19.0 1095 3748048 180BNA036****A CSPH*4812A** 353(A,B)AV036080 37,800...
  • Page 23 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747823 187BNA048****A CAP**6024A** 353(A,B)AV060100 48,500 39,500 12.9 16.5 1410 1070 3747824 187BNA048****A CAP**6024A** 353(A,B)AV060120 49,000 40,500 13.0 16.5 1425 1260 3747732 187BNA048****A CAP**6024A**+UI...
  • Page 24 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747753 187BNA048****A CNPV*6024A** 313*AV060110 48,500 40,000 13.1 16.5 1395 1145 3747754 187BNA048****A CNPV*6024A** 313*AV060135 48,500 40,500 12.9 16.0 1420 1255 3747828 187BNA048****A CNPV*6024A**...
  • Page 25 COMBINATION RATINGS CONTINUED Capacity ID CFM AHRI Ref. Outdoor Model Indoor Coil Furnace Model SEER Number Model Number High High 3747792 187BNA048****A CSPH*6012A**+UI 355(A,C)AV060100 48,500 40,000 12.6 16.0 1395 1115 3747793 187BNA048****A CSPH*6012A**+UI 355(A,C)AV060120 48,500 40,000 12.9 16.5 1360 1090 3747803 187BNA048****A FE4AN(B,F)005+UI...
  • Page 26 TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces equipped with TDR.
  • Page 39 CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 187BNA024 HI 22.50 21.30 20.20 18.90 17.60 16.30 14.90 13.40 67.50 77.40...
  • Page 40 CONDENSER ONLY RATINGS* (CONTINUED) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 180BNA036 HI 29.20 28.40 27.50 26.40 25.20 23.80 22.30 20.50 67.10...
  • Page 41 CONDENSER ONLY RATINGS* (CONTINUED) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 187BNA060--- A HI 52.30 49.80 47.20 44.50 41.60 38.60 35.40 32.00...
  • Page 42 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 187B / 180B GENERAL 2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1- -phase type with class B insulation and permanently lubricated Outdoor- -mounted, air- -cooled, split- -system air conditioner unit bearings.
  • Page 43 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01- -in. wc. 2. This product is qualified for low ambient cooling operation (below 55_F/12.8_C) when used with an Infinity User Interface ONLY. 3.
  • Page 44 EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 03/10 Catalog No. PDS180---187B---02 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: PDS180--- 187B--- 02...

This manual is also suitable for:

Evolution 180b

Table of Contents