Bryant AIR CONDITIONER WITH PURONR 113A Product Data
Bryant AIR CONDITIONER WITH PURONR 113A Product Data

Bryant AIR CONDITIONER WITH PURONR 113A Product Data

Legacy-rnc series air conditioner with puron
Hide thumbs Also See for AIR CONDITIONER WITH PURONR 113A:

Advertisement

Model 113A
Legacy- -RNC Series Air Conditioner with Puronr
the environmentally sound refrigerant
Bryant's Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 113A has been designed utilizing Bryant's Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth's ozone
layer. Bryant's air conditioning system with Puron refrigerant
meets the Energy Starr guidelines for energy efficiency.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
Sound
Comfort
Reliability
A05233
Durability
DuraGuardt protection package:
Applications
Warranty
S
13 SEER/11 EER
S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
S
Sound level as low as 76 dBA
S
System supports Thermidistatt or standard thermostat
controls
S
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
S
Front- -seating service valves
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
Filter drier
S
Balanced refrigeration system for maximum reliability
S
Solid, Durable sheet metal construction
S
Dense wire coil guard
S
Baked- -on, complete coverage, powder paint
S
Long- -line - - up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for
more information.)
S
Low ambient (down to - -20_F) with accessory kit
S
5 year limited compressor warranty
S
5 year limited parts warranty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIR CONDITIONER WITH PURONR 113A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bryant AIR CONDITIONER WITH PURONR 113A

  • Page 1: Product Data

    Bryant’s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 113A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Prod- Tier SEER Major Series Family 1=AC Legacy 3=13 SEER A=Puron the environmentally sound refrigerant Feature Puron Refrigerant 13 SEER Scroll Compressor Dense Wire Coil Guard Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit...
  • Page 3: Physical Data

    * For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1- -STAGE AIR CONDITIONER APPLICATIONS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft or when there is more than 20 Ft vertical separation between indoor and outdoor units.
  • Page 4: Accessories

    ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. TSTATBBPRH01--- B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TSTATBBPAC01--- B Thermostat --- Auto Changeover, 7--- Day Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATBBNAC01--- C Thermostat --- Auto Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATBBBAC01--- B Builder’s Thermostat --- Manual Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATBBSEN01--- B...
  • Page 5 55_F (12.8_C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 6: Electrical Data

    Accessory Description and Usage (Listed Alphabetically) (Continued) 14. Winter Start Control This control is designed to alleviate nuisance opening of the low- -pressure switch by bypassing it for the first 3 minutes of operation. ELECTRICAL DATA OPER COMPR UNIT VOLTS* V/PH SIZE 48.0...
  • Page 7 3--- 460--- 3--- 208/230--- 1--- 230--- 1--- 230--- 208---...
  • Page 8: Combination Ratings

    COMBINATION RATINGS Unit Size --- Indoor Voltage & Model Series *CAP**1814A** CAP**1814A** CAP**2414A** CAP**2414A** CAP**2417A** CAP**2417A** CAP**2417A** CNPV*1814A** CNPV*1814A** CNPV*2414A** CNPV*2414A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPH*2417A** 018--- A CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPF*2418A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A** FY4ANF018 FY4ANF024 FX4CNF018 FX4CNF024...
  • Page 9: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED Unit Size --- Indoor Voltage & Model Cap. BTUH Series *CAP**2414A** CAP**2414A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**3014A** CAP**3014A** CAP**3017A** CAP**3017A** CAP**3017A** CNPV*2414A** CNPV*2414A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*3014A** CNPV*3014A** CNPV*3017A** 024--- A CNPV*3017A** CNPV*3017A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*3017A** CNPH*3017A** CNPH*3017A** CNPF*2418A** CSPH*2412A**...
  • Page 10 COMBINATION RATINGS CONTINUED Unit Size --- Indoor Total Cap. Voltage & Model Series CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** 024--- A FY4ANF024 FY4ANF030 FX4CNF024 FX4CNF030 FF1ENP024 FF1ENP030 FV4BNF002 FV4BNF003 *CAP**3014A** CAP**3014A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3614A** CAP**3614A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3621A** CAP**3621A**...
  • Page 11 COMBINATION RATINGS CONTINUED Unit Size --- Indoor Total Cap. Voltage & Model Series CNPF*3618A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3612A** CSPH*3612A** CSPH*3612A** 030--- A FY4ANF030 FY4ANF036 FX4CNF030 FX4CN(B,F)036 FF1ENP030 FF1ENP036 FV4BNF002 FV4BNF003 FV4BNF005 *CAP**3617A** CAP**3614A** CAP**3614A** CAP**3617A** CAP**3617A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4224A**...
  • Page 12 COMBINATION RATINGS CONTINUED Unit Size --- Indoor Total Cap. Voltage & Model Series CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPF*3618A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*4212A** 036--- A CSPH*4212A** CSPH*4212A** FY4ANF036 FY4ANF042 FX4CN(B,F)036 FX4CN(B,F)042 FF1ENP036 FV4BNF002 FV4BNF003 FV4BNF005 FV4BNB006 *CAP**4221A** CAP**4221A** CAP**4221A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4817A** CAP**4817A** CAP**4817A**...
  • Page 13 COMBINATION RATINGS CONTINUED Unit Size --- Indoor Total Cap. Voltage & Model Series CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPF*4818A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4812A** 042--- A CSPH*4812A** CSPH*4812A** FY4ANF042 FY4ANF048 FX4CN(B,F)042 FX4CN(B,F)048 FV4BNF003 FV4BNF005 FV4BNB006 CAP**4817A** CAP**4817A** *CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**6021A** CAP**6021A**...
  • Page 14 { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 15 DETAILED COOLING CAPACITIES EVAPORATOR Capacity Capacity Total MBtuh{ System MBtuh{ KW** Total Sens} Total Sens} 113ANA018---A Outdoor Section With *CAP**1814A**Indoor Section 20.46 10.76 1.21 19.55 18.79 13.26 1.22 17.95 17.27 15.73 1.22 16.49 16.78 16.78 1.23 16.15 20.79 11.28 1.24 19.83 19.11 14.10...
  • Page 16: Detailed Cooling Capacities

    DETAILED COOLING CAPACITIES EVAPORATOR Capacity Capacity Total MBtuh{ System MBtuh{ KW** Total Sens} Total Sens} 27.11 14.29 1.61 25.97 24.89 17.62 1.61 23.81 22.86 20.91 1.61 21.86 22.24 22.24 1.61 21.43 27.54 14.98 1.64 26.35 25.31 18.74 1.64 24.19 23.37 22.46 1.65 22.36...
  • Page 17 DETAILED COOLING CAPACITIES EVAPORATOR Total Capacity Capacity Sys- MBtuh{ MBtuh{ Total Sens} Total KW** 33.13 17.60 2.01 31.70 30.12 21.64 2.01 28.78 27.50 25.68 2.01 26.29 26.93 26.93 2.01 25.94 33.69 18.46 2.05 32.21 30.64 23.04 2.05 29.26 1000 28.16 27.55 2.06 26.95...
  • Page 18 DETAILED COOLING CAPACITIES EVAPORATOR Total Capacity Capacity Sys- MBtuh{ MBtuh{ Total Sens} Total Sens} KW** 40.12 21.34 2.48 38.42 36.62 26.34 2.47 35.03 1050 33.54 31.31 2.46 32.11 32.88 32.88 2.46 31.70 40.72 22.34 2.54 38.96 37.19 27.96 2.53 35.54 1200 34.30 33.50...
  • Page 19 DETAILED COOLING CAPACITIES EVAPORATOR Total Capacity Capacity Sys- MBtuh{ MBtuh{ Total Sens} Total Sens} KW** 48.51 25.52 3.33 46.40 44.49 31.40 3.31 42.53 1225 40.85 37.25 3.29 39.08 39.76 39.76 3.29 38.32 49.22 26.65 3.40 47.02 45.18 33.25 3.38 43.15 1400 41.71 39.81...
  • Page 20 DETAILED COOLING CAPACITIES EVAPORATOR Total Capacity Capacity Sys- MBtuh{ MBtuh{ Total Sens} Total Sens} KW** 55.04 28.49 3.35 52.62 49.86 34.52 3.35 47.63 1400 45.26 40.60 3.35 43.30 44.65 44.65 3.35 42.99 56.06 29.65 3.42 53.54 50.79 36.35 3.42 48.45 1600 46.36 43.45...
  • Page 21 DETAILED COOLING CAPACITIES EVAPORATOR Total Capacity Capacity Sys- MBtuh{ MBtuh{ Total Sens} Total Sens} KW** 67.65 35.66 4.15 64.56 62.07 43.94 4.10 59.24 1750 57.01 52.17 4.06 54.45 55.50 55.50 4.04 53.42 68.69 37.30 4.26 65.46 63.07 46.60 4.21 60.11 2000 58.17 55.80...
  • Page 22 GUIDE SPECIFICATIONS GENERAL System Description Outdoor- -mounted, air- -cooled, split- -system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air- -cooled coil, propeller- -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings.

Table of Contents

Save PDF