Bryant 180B Product Data

Bryant 180B Product Data

2-5 ton evolution 20 air conditioner with puron refrigerant
Hide thumbs Also See for 180B:

Advertisement

180B (2 - - 5 Ton)
EVOLUTIONr 20 AIR CONDITIONER
WITH PURONr REFRIGERANT
the environmentally sound refrigerant
Bryant's air conditioners with Puron r refrigerant provide a
collection of features unmatched by any other family of
equipment. The 180B has been designed utilizing Bryant's
Puronr refrigerant. The environmentally sound refrigerant allows
consumers to make a responsible decision in the protection of the
earth's ozone layer.
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
S
S
S
S
Comfort
TM
S
Reliability
S
S
S
S
S
S
S
S
S
S
Durability
DuraGuard Plust protection package:
S
S
S
Applications
S
14 - - 20 SEER / 11.6 - - 14.5 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 66 dBA
Electronic ECM ball bearing outdoor condenser fan
motor
Compressor sound hood
Forward- -swept condenser fan blade
Quiet mount split post compressor grommets
System supports Evolutiont Control or standard
2- -stage thermostat controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime service cost.
Front- -seating service valves
2- -stage scroll compressor
Internal pressure relief valve
Internal thermal overload
Low pressure switch
High pressure switch
Filter drier
Crank case heater standard
Balanced refrigeration system for maximum reliability
Solid, Durable sheet metal construction
Steel louver coil guard
Baked- -on, complete outer coverage, powder paint
Long- -line - - up to 250 feet (76.2 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 180B

  • Page 1: Product Data

    2- -stage thermostat controls Reliability Puronr refrigerant - - environmentally sound, won’t Bryant’s air conditioners with Puron r refrigerant provide a deplete the ozone layer and low lifetime service cost. collection of features unmatched by any other family of equipment. The 180B has been designed utilizing Bryant’s Front- -seating service valves Puronr refrigerant.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Minor Family Series Series 1=AC 0 =21 B=Puron 0=Not Evolution SEER Standard Defined Original 208--- 230--- 1 Series Nominal Defined Defined Series the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a manufacturer’s...
  • Page 3: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
  • Page 4: Long Line Applications

    LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
  • Page 5: Electrical Data

    ELECTRICAL DATA OPER FUSE* UNIT COMPR WIRE WIRE LENGTH LENGTH VOLTS* * or SIZE --- SIZE{ SIZE{ ft (m)} ft (m)} MODEL V--- PH --- Hz SERIES 60°C 75°C 60°C 75°C AMPS 024--- A 208/230 ---1 ---60 52.0 10.30 14.3 14.00 14.00 55 (16.8)
  • Page 6 ACCESSORIES KIT NUMBER KIT NAME 024--- A 036--- B 048--- A 060--- A KSAHS2301AAA HARD START KIT KSAHS2401AAA HARD START KIT KSAHS2501AAA HARD START KIT KSAHS2601AAA HARD START KIT KSASF0101AAA SUPPORT FEET KSATX0201PUR KSATX0301PUR KSATX0401PUR KSATX0501PUR x = Accessory CONTROLS CONTROL DESCRIPTION SYSTXBBUID01--- D...
  • Page 7: Accessory Usage Guideline

    3. Outdoor Air Temperature Sensor Required for use on all zoning systems. Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 10 Wall...
  • Page 11 TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 17: Condenser Only Ratings

    CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 180BNA024****A HI 22.50 21.30 20.20 18.90 17.60 16.30 14.90 13.40 67.50 77.40...
  • Page 18 CONDENSER ONLY RATINGS* (CONTINUED) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 180BNA036****B LOW 18.80 18.20 17.60 16.80 15.90 14.80 13.70 12.40 64.30...
  • Page 19 CONDENSER ONLY RATINGS* (CONTINUED) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 180BNA060****A HI 48.10 46.80 45.30 43.60 41.60 39.30 36.80 33.90 68.50...
  • Page 20 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 180B GENERAL 2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1- -phase type with class B insulation and permanently lubricated Outdoor- -mounted, air- -cooled, split- -system air conditioner unit bearings.
  • Page 21 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01- -in. wc. 2. This product is qualified for low ambient cooling operation (below 55_F/12.8_C) when used with an Infinity User Interface ONLY. 3.
  • Page 22 EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 09/12 Catalog No. PDS180B---05 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: PDS180B--- 04...