Discard the o- rings. Note: Be careful not to scratch the o-ring groove. 5. Pass the clamps through the carrier straps. 2. Remove the ring from the split ring. MSA 014 (L) Rev. 0 - 10110431...
3. Pass the waist strap through the shoulder strap. a. Position the clamps at the edges of the Note: Make sure the label. stiffener is properly oriented. MSA 014 (L) Rev. 0 - 10110431...
4. Attach the hose strap to the ring. c. Use the o-ring removal tool to slide the o-ring into the groove. Note: Be careful not to scratch the o-ring groove. MSA 014 (L) Rev. 0 - 10110431...
Page 7
125 +/- 25 in.lbs. 2. If necessary, use an 11/16” crowfoot and inch-pound torque wrench to connect the second stage regulator hose and tighten to 125 +/- 25 in.lbs. MSA 014 (L) Rev. 0 - 10110431...