Download Print this page

Philio PAT12 Manual page 3

Co2 sensor

Advertisement

The Sensor supports Command Classes including...
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V3,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SENSOR_MULTILEVEL_V11,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Over The Air (OTA) Firmware Update
The device supports Z-Wave firmware update via OTA.
Before starting the update, please remove the front case of the device otherwise the
hardware check will fail.
Let the controller into firmware update mode, and press the front tamper key once to
start the update.
After firmware download is completed, the LED light will flash intermittently.
Overview
Specification
Rated Voltage
Range
Operating Temperature
Storage Temperature
Location
Dimension
CO2
Frequency Range
RF Maximum Power (peak) +5dBm (peak)
RF Maximum Power
(Average)
RF Modulation Type
FCC ID
3
DC5V from USB
Minimum 40M in door and 100M in outdoor line of
sight
-10°C
~ 40°C (85% humidity)
-20 C ~ 60°C
Indoor use only
65(L) x 44.1 (W) x 56.3 (H) mm
0-5000ppm
868.40MHz; 869.85MHz (EU)
908.40MHz; 916.00MHz (USA/Canada)
916MHz (Israel)
922.5MHz, 923.9MHz, 926.3MHz (JP)
-10dBm (Average)
FSK (Frequency-Shift Keying)
RHHPAT12

Advertisement