Mitsubishi Electric MR-J5 User Manual page 55

Ac servo system, partner's encoder for melservo-j5
Hide thumbs Also See for MR-J5:
Table of Contents

Advertisement

Fabricating the encoder cable used to connect the servo amplifier and interpolator
Fabricate the encoder cable using the MR-J3CN2 connector set and junction connector as shown below. The encoder cable
may be as long as 30 m.
■Encoder cable 1
Connector set (optional)
MR-J3CN2
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
(3M)
*2
2
6
10
LG
4
8
MRR
1
5
9
P5
3
7
MR
*3
View from the wiring side.
or
Connector set: 54599-1019
*2
(Molex)
2
4
6
8
10
LG
MRR
1
3
5
7
9
P5
MR
*3
View from the wiring side.
*1 Encoder cables that meet the following specifications are recommended.
Wiring length
Up to 5 m
Up to 10 m
Up to 20 m
Up to 30 m
*2 The signals of pins 3 and 4 of the CN2L connector are as follows.
Pin 3: MR2
Pin 4: MRR2
*3 Do not connect anything to the pins that are marked with a diagonal line. Securely connect the external conductor of the shielded cable
to the ground plate and fix it to the connector shell.
Page 4 Shielding CN2, CN2A, CN2B, and CN2C connectors
Servo amplifier-side
*1
P5
1
LG
2
*2
MR
3
*2
MRR
4
Plate
SD
Number of paired LG and P5 connections
1 pair
2 pairs
3 pairs
4 pairs
MQ10 side
Plug: 10114-3000PE (3M)
Shell kit: 10314-52F0-008 (3M)
13
5 V
11
0 V
5
SQ
6
SQ_X
Plate
FG
Wire size
AWG 22
1 LINEAR ENCODER
1.5 Linear encoder manufactured by Magnescale
1
53

Advertisement

Table of Contents
loading