DETAILED CONTROLS AND GAUGES
3. Check the time remaining until maintenance.
(a): Time remaining until maintenance
(b): Default setting for maintenance interval
When only checking the time remaining until maintenance,
press back switch (8) twice.
The screen will return to the normal operation monitor
screen.
When canceling time remaining until maintenance and
returning to the default time setting, press inout confirma-
tion switch (11). The screen will switch to the default setting
screen.
4. After checking the time on the default setting screen, press
input confirmation switch (11).
The screen will return to the maintenance screen.
(Press back switch (8) to return to the previous screen.)
User Mode Adjustment Switch
Press this switch (7) to set to fan reverse rotation and to adjust
the set value for the economy mode.
Fan Reverse Rotation
1. Press switch (7) and the monitor display screen changes to
the fan reverse rotation and economy mode adjustment
screen show on the right.
01: Fan reverse rotation menu
02: Economy mode adjustment menu