MACHINE OPERATIONS AND CONTROLS
Drain Water And Sediment from Fuel Tank
1. Set a container under drain hose (1) to catch the drained
fuel.
2. Pull out drain hose (1) from the clip on the chassis and
point the hose tip to the container.
3. Open drain valve (2) and drain the sediment and water
accumulated at the bottom together with the fuel.
4. Close drain valve (2) when only clean fuel begins to flow
out, and put away drain hose (1) to the original place.
Check for Water and Sediment in Water Separator, Drain Water
The water separator is installed at the bottom of the fuel pre-filter.
1. Open up the front left side cover of the engine hood.
2. It is possible to judge the water level and amount of sedi-
ment by looking through transparent cap (2). If there is any
water or sediment collected at the bottom, set a container
to catch the drain water under drain hose (3).
3. Loosen drain valve (1) and drain the water.
4. When fuel comes out from drain hose (3), tighten drain
valve (1) immediately.
Tightening torque: 0.2 - 0.45N·m ( 0.02 -0.046 kgf·m)
Check Oil Level in Hydraulic Tank, Add Oil
q The parts and oil are at high temperature immediately after the engine is stopped, and may cause
burns. Wait for the temperature to go down before starting the work.
q When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it.
3-80
WARNING
OPERATION