Komatsu PC800-8 Operation & Maintenance Manual page 242

Hydraulic excavator
Hide thumbs Also See for PC800-8:
Table of Contents

Advertisement

MAINTENANCE PROCEDURE
NOTICE
When inserting the element, if the rubber at the tip is swol-
len or the outer element is not pushed in straight, and
cover (3) is assembled by force to hook (2), there is danger
that the hook and air cleaner body may be damaged, so be
careful when assembling.
12. Install cover (3) as follows.
1) Align cover (3) with the element.
2) Hook the tip of hook (2) to the protruding part of the air
cleaner body and lock it in position.
3) When locking hooks (2) in position, apply the hooks in
turn on opposite sides (top, bottom, left, right) in the same
way as when tightening bolts.
4) Always install cover (3) so that the evacuator (4) is facing
the ground (A).
5) When cover (3) is installed, check that the clearance
between the air cleaner body and cover (3) is not too large.
If it is too large, install again.
13. When replacing the element, push the indicator button at
the bottom of the air cleaner to reset it.
Install Air Cleaner Element
1. Open the engine hood at the front side of the machine,
remove 6 hooks (2), then remove cover (3).