Download Print this page

Farfisa ST 720 Technical Manual page 52

Electronic call systems

Advertisement

Si 27MO/1
INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 2 MAIN COMMON STATIONS (multiple entrance)
Q.ty
Article
...
KM 810W
...
ST 720W
...
PT 510EW
...
PT 526EW
X
PRS240
1
PRS220
2xX
1473
2+X
PA **
2+X
SE **
Door station series Mody (for right item set see on pages 16÷19)
1 row
...
MD71÷74
2+X
MD10-11-12
...
MD21 ÷ 24
...
MD20 - 50
2+X
MD82 ÷ 812
2+X
MD92 ÷ 912*
2+X
MD30
Door station series Matrix (for right item set see on pages 24 and 25)
...
MA71÷73
2+X
MA10P-11P-12P
...
MA20-22-24
...
MA61÷63
...
MA91 ÷ 93 *
Door station series Profilo (for right item set see on pages 28 and 29)
...
PL71÷73
2+X
PL10P-11P-12P
...
PL20 ÷ 24
... Refers to number of users.
X Refers to the number of stairways.
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions.
As the basic system described on page 36, with the following variations:
- The audio functions and door lock opening are automatically switched to the door
station which has made the call and remain in this state until a call from another entrance
is received.
- Services to secondary door stations are independent and can be operated at the same
time.
Notes
- You can also use Prestige and TM push-button panels. For the latter series you must
request the version with separate common terminals.
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the installation
instructions on page 35.
S
- For wires dimensioning refer to the installation recommendations and table on page
35.
- Telephones can be used instead of intercoms (see "telecommunication" section).
T
- For other types of push-button panels see pages 30 and 31 or the general catalogue.
-
P
T
-
K
M
Description
Compact series intercom with 1 call button
Studio series modular intercom
Project series intercom with 1 call button
Project series modular intercom
Power supply with electronic ringing generator
Power supply
Exchanger
Door release push-button (optional)
Electric door lock (12VAC-1A)
2 row
MD71÷74
Module frames with back box
MD10-122-124 Modules for electric door speaker
MD222 ÷ 228
Button modules
MD20 - 50
Blank and info modules
MD82 ÷ 812
Hood covers
MD92 ÷ 912*
Rain shelters with module frames
MD30
Electric door speaker (amplifier)
Module frames with back box
Modules with integrated audio amplifier
Blank and button modules
Front frames
Rain shelters with module frames
Module frames with back box
Modules with integrated audio amplifier
Blank and button modules
(MT11 - Gb2006)
The main entrance push-button panel must
have separate common terminals. One common
terminal for each secondary door station. Buttons of
the Mody series can be divided into 2-button groups.
Common terminals of Matrix and Profilo push but-
tons cannot be separated.
Call button modules series Mody
50
Floor call
This work diagram allows for differ-
entiating the floor-call from the call
from the push-button panel.
FP
9
Floor-button
PT510E
PT526E
FP
9
Floor-button
ST720
KM810
7
C+
PRS240
common of buttons 1
and 2
to separate common of
buttons cut here
common of buttons 3
and 4

Advertisement

loading