Download Print this page

Farfisa ST 720 Technical Manual page 244

Electronic call systems

Advertisement

POWER SUPPLIES AND SERVICE MODULES
Timed power supply
140
"
5
1
/
89
2
"
1
3
/
2
1181E. Timed supply for videointercoms, CCD
cameras, electric lock and name-plate lights,
etc.
Technical data
Input voltage:
127 or 220-230Vac
Frequency:
50/60Hz
Power:
48VA
Switch-ON time:
100 sec.
Housing:
DIN 8 modules A
Weight:
0.95Kg.
Approved by:
VDE according to the safety
standard EN60065
Operating temperature:
0°÷40°C
Maximum permissible humidity: 90%RH
Notes
- The power supply is not provided with fuses,
but all of its outputs are protected against
overloading and short circuiting by tempera-
ture sensors. To reset the power supply, pow-
er must be cut off for about one minute and
can be restored after having eliminated the
defect.
- The power supply must be installed in a dry
place and can be fixed on DIN bar or on a wall
by using the expansion plugs.
Output terminals
A Output voltage 13Vac for:
-name plate light, exchangers and climatized
camera (continuous service 0.6A)
-electric door lock and bells (intermittent
service 1A)
-
Ground for AC power supply
F Ground for DC power supply
H Continuous output 21Vdc-1A (timed op-
eration)
C- Electronic bell output for external calls 0.25A
4 Control switch-ON input from monitors
X Positive voltage output not stabilized 12Vcc-
0.2A
3+ Stabilized positive voltage output 8Vcc-
0.1A
Transformers
74
"
15
2
/
16
70
89
3
2
"
/
4
3
1
"
/
2
PRS210ED. Transformer with electronic bell
used to power the 1+1 intercom system with
electronic call.
Technical data
Input voltage
Power:
Output voltage:
Ringing frequency:
Maximum load:
Maximum of intermittent load: 1A
Housing:
Weight:
Operating temperature:
Maximum permissible humidity: 90%RH
Output terminals
A Output voltage 13Vac for:
-name plate light, exchangers and climatized
camera (continuous service 0.6A)
-electric door lock and bells (intermittent
service 1A)
-
Ground
C- Negative electronic bell output 10Vpp-0.25A
PRS210.
It can replace PRS210ED in all the applica-
tions where the electronic call generation is not
required. Used to power 13Vac devices;
supplementary amplified door stations, name
plate light, additional door locks, etc.
Technical data
Input voltage
Power:
Output voltage:
Maximum load:
Maximum of intermittent load: 1A
Housing:
Weight:
Approved by:
VDE according to the safety
standard EN60065
Operating temperature:
Maximum permissible humidity: 90%RH
Output terminals
/
Output voltage 13Vac for:
-name plate light, exchangers and climatized
camera (continuous service 0.6A)
-electric door lock and bells (intermittent
service 1A)
242
(MT11 - Gb2006)
Service modules
65
2
9
"
/
16
70
2
3
"
/
4
RL37D. Supplementary call module
When installed in 1+1 intercom and 4+1 video
intercom systems with electronic call, it pro-
vides a supplementary input for external calls,
enables supplementary video power supply
127 or 220-230Vac
and provide a second ringer for floor calls.
15VA
13Vac
Technical data
450Hz modulated
Power supply:
0.6A
Stand-by current:
Max. switching current:
DIN 4 modules A
Housing:
0.42Kg
Operating temperature:
0°÷40°C
Max. permissible humidity:
Terminals
A
13Vac alternate voltage input
-
ground
H
timed positive continuous voltage input
21Vdc
IV supplementary power supply enabling
C
common contact of relay
NA normally open contact of relay
NC normally closed contact of relay
1P electronic call input
1M electronic call output enabled from termi-
nal 1P
CP electronic call output
Note: Remove the cover and move jumper J2
to change the sounds of electronic ringer.
Position 1-2: modulated note
Position 2-3: continuous note
127 or 220-230Vac
15VA
A
13Vac
0.7A
1P
DIN 3 modules A
0.42Kg
0°÷40°C
1473. EXCHANGER. See page 33.
1471. RELAY UNIT. See page 34.
1471E. RELAY UNIT. See page 34.
1472. 2-CONTACT RELAY UNIT. See
page 34.
65
2
9
"
/
16
89
3
1
"
/
2
13Vac
40mA
1A (24V)
DIN 4 A modules
0° ÷ 50°C
90% RH
IV
H
CP
1M
NC
NA
C

Advertisement