Download Print this page

Farfisa ST 720 Technical Manual page 206

Electronic call systems

Advertisement

INTERCOM-TELEPHONE INTERFACE
140
"
5
1
/
89
2
3
1
/
2
FT11D. Intercom-telephone interface.
It allows the connection of the trunk line and the
intercom system to home telephone.
Technical data
Power supply
Maximum power consumption 7VA
Flashing time (button "R")
Ringing Voltage
Operating temperature
Maximum humidity
Housing
Note
The model is not provided with fuses, but it is
protected against overloading or short-circuit-
ing by temperature sensors (thermoprotector).
In order to reset them, it is necessary to cut off
the mains voltage for about one minute. Recon-
nect power after correcting the fault.
Terminals
Tip/ Ring trunk line connection
L-/ L+
telephone connection
0/ 127
input voltage 127Vac
0/ 230
input voltage 230Vac
1 audio transmission
2 audio receiver
3 ground
4 terminal connected to ground. It can be iso-
lated by cutting W5 jumper. The normally
open contact of relay, is connected between
terminals 4 and 5.
5 lock release - max 1A (common relay con-
tact)
6 intercom call input (12Vac - 150 mA)
7 normally closed contact of relay
INSTALLATION
The intercom-telephone interface FT11D in
DIN housing 8 modules A can be installed in
suitable electrical box provided with bar sup-
F
port in compliance with DIN 46277 standards.
It can also be fixed to the wall with two screws
A
and expansion plugs not supplied with the prod-
uct. The two plastic protections of the ter-
R
minal boards must be mounted in case of
wall installation. They can be eliminated in
case of installation on DIN bar in electrical box.
T
E
L
74
"
15
2
/
16
"
Telephone and electrical connections
- Connect the two wires of the trunk line (tele-
phone pair) to terminals TIP and RING.
Trunk line
127/230Vac
80 ÷ 330msec
48Vac - 15mA
0° ÷ +40°C
85% RH
DIN 8 modules A
- Connect the two wires of the telephone to
terminals L- and L+ (telephone pair). The maxi-
mum distance between the interface and the
last telephone is 350m with 0.6mm² pair. Do
not lay the telephone cables together with
electrical cables.
- Connect the five wires of the intercom system
to terminals 1, 2, 3, 5 and 6.
- Connect the two wires of the electrical mains
to terminals 0 and 230 (or 0-127 according to
the ratings of the mains). It is necessary to
provide a disconnecting and safety bipo-
lar switch before the device.
- Insert the 2 plastic protection of the terminal
covers supplied with the product.
PROGRAMMING THE TELEPHONE
ST740W
Both a standard telephone and model ST740
can be used as internal extension.
When using art.ST740 it is necessary to pro-
gram it in order to use the buttons dedicated to
intercom functions. For information on pro-
gramming see page 194. Following are the
TIP
RING
codes that can be assigned to the intercom
buttons.
Button
OPERATION AND USE
L+
Do not open or tamper with the device
since it contains high voltages inside. In-
stallation and maintenance must be done
exclusively by specialized personnel.
Please consider that also if the telephone inter-
face is ON for outgoing / incoming calls the
1
telephone is connected to the trunk line directly.
2
To operate the telephone interface set the switch
on "I".
3
W5
A flashing indicator (LED) shows the system is
4
working properly.
5
6
Incoming outside calls
7
- When receiving a call from the trunk line it is
enough to pick up the handset and to answer.
Outgoing external calls
- Pick up the handset.
- Wait for the dial tone of public exchanger.
- Dial the number.
Intercom connection without an outdoor
230V
127V
incoming call
- Pick up the handset.
- Wait for the dial tone of public exchanger.
(ST740)
(Standard) - the "R" key twice (R+R) in a 3-
230Vac
204
(MT11 - Gb2006)
Code
RR
RRRR
can be programmed with a maxi-
mum number of 6 digits (emer-
gency number, telephone provider
special services).
- press
seconds lapse of time.

Advertisement

loading