Ebyte E-840-TTL-4G02 User Manual page 12

4g/lte serial module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd
Receive:0xAA 0XFE 0x55 ID data length Data
For example: AA FE 55 02 03 11 22 33
11 22 33:real data
Demonstration:
Take SOCK2 as an example: ,
Transmit:+++(do not add new line for transmitting )
Transmit:AT+VER(add new line for transmitting )
same time
+OK=E840-TTL(4G-02)_V1.0
Transmit : AT+SOCK2=1,TCPC,116.62.42.192,31687
Transmit:AT+LINKSTA2
+OK=Connect
Transmit:AT+POTOCOL=ON
+OK
Transmit:AT+POTOCOL
+OK=ON
AT+REBT
+OK
Waiting for the radio to restart, SOCK2 will automatically establish a connection with the server. After the connection is
started, data can be transmitted to each other via protocol.
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
+OK
//02: SOCK2 link,
//enter AT command
//read version info. And enter AT command setting at the
//open SOCK2 and configure the network server
parameters that SOCK2 will connect to (the parameter used
here is Ebyte test server, not recommended for users)
//read if SOCK2 has started connection with server
// open protocol transmission mode
//inquire if protocol transmission is on
//restart
E840-TTL(4G-02)User Manual