Printed Circuit Board Connector Wiring Diagram; Wall Mounted Type - Daikin D Series Service Manual

Inverter multi for 2 rooms
Hide thumbs Also See for D Series:
Table of Contents

Advertisement

Printed Circuit Board Connector Wiring Diagram

1.

Printed Circuit Board Connector Wiring Diagram

1.1

Wall Mounted Type

1.1.1
FTK(X)S20~35D
Connectors
1)
2)
3)
4)
5)
6)
7)
8)
Note:
Other designations
1)
2)
3)
4)
5)
6)
7)
8)
9)
22
S1
Connector for fan motor
S6
Connector for swing motor (horizontal blades)
S21
Connector for
S26
Connector for display PCB
S27, S29, S36
Connector for control PCB
S28
Connector for signal receiver PCB
S32
Connector for heat exchanger thermistor
S35
Connector for INTELLIGENT EYE sensor PCB
V1
Varistor
JA
Address setting jumper
JB
Fan speed setting
JC
Power failure recovery function (auto-restart)
Refer to page 205 for detail.
SW1
Forced operation ON / OFF switch
LED1
LED for operation (green)
LED2
LED for timer (yellow)
LED3
LED for INTELLIGENT EYE (green)
LED A
LED A for service monitor (green)
FU1
Fuse
(3.15A)
RTH1
Room temperature thermistor
centralized control
(HA)
when compressor is OFF on thermostat