6.0 TROUBLE-SHOOTING

GENERAL TROUBLESHOOTING GUIDE

PROBLEM
Cooking indicator light fails to
light with Timer set.
Steam fails to enter cooking
compartment with cooking
indicator light on.
PROBABLE CAUSE
a.
Main power circuit breaker
tripped.
b.
Door interlock switch
contacts not closed.
c.
Door interlock switch faulty.
d.
Indicator light burned out.
e.
Faulty timer contacts.
f.
Faulty wiring.
a.
Faulty wiring.
a.
Standby thermostat not set
correctly.
b.
Faulty thermostatic switch.
c.
HOLD set on timer.
17
REMEDY
a.
Locate external circuit
breaker for incoming power
and place in ON position.
b.
Shut cooker door to close
switch contacts. Check
alignment of door with
switch.
c.
Replace switch.
d.
Replace light.
e.
Replace timer.
f.
Inspect condition of wire
and tightness of all
connections. Correct as
needed.
a.
Inspect condition of wire
and tightness of all
connections. Correct as
needed.
a.
Adjust the thermostat
lower.
b.
Replace thermostat.
Rotate timer knob to 'OFF'
c.
position.