Tektronix IntelliFrame VX1410A Instruction Manual page 216

Vxibus mainframes
Table of Contents

Advertisement

VXIMonitor:TINTerval
VXIMonitor:TINTerval?
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Sets or queries the time interval the VXI Monitor monitors the VXI bus. The
VXI monitor monitors the bus for the specified number of seconds and reports
any detected VXI Monitor event.
The factory default setting is 10 seconds.
VXIMonitor:TINTerval <time>
VXIMonitor:TINTerval?
<time>
<NRf>
1 N 2147483647
MIN
MAX
Not Applicable
–222, "Data Out of Range"
You attempted to set the interval to an illegal value.
–221, "Settings Conflict."
You attempted to set the interval while the VXI Monitor was executing.
None
Command: VXIM:TINT 100
VXIM:TINT?
Query:
Response: 100
VXIMonitor:REPeat
VXIMonitor:STATe
VXIMonitor Subsystem
Query response
<NR1>
1
2147483647
3–159