UNLOADING

Unloading from Trailer:
Lever Bar (also known as a Mule, Johnson
Bar, J-bar, Lever Dolly, or Pry Lever)
Move the merchandiser as close as possible to
its permanent location and remove all packaging .
Check for damage . Remove all separately
packed accessories . Improper handling may
cause damage to the merchandiser when
unloading .
To avoid damage:
1 . Do not drag the merchandiser out of the
trailer . Use a Johnson bar (mule) . Use a
forklift or dolly to remove the merchandiser
from the trailer .
2 . Use caution when moving case to
setup location . Use care to not damage
refrigeration system . Confirm there are
no refrigerant leaks during startup of the
case(s) .

SHIPPING SKID

Each merchandiser is shipped on a skid to
protect the merchandiser's base, and to make
positioning the case easier .
Do NOT stand or walk on top of
merchandiser. Do not store items or
flammable materials atop the unit.
Do NOT remove shipping skid until
the merchandiser is positioned for
installation.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Remove the top of the crate and detach walls
from each other (if provided) . Lift crate from
the skid . Unscrew the case from the skid . The
fixture can now be lifted off the crate skid . Lift
only at base of skid! Remove any braces and/or
skids attached (blanket wrapped merchandiser
may have skids) .
Remove #7 x 2" Philips screws
from merchandiser base
DO NOT LAY MERCHANDISER OVER
ON THE FLOOR TO REMOVE SKID .
Once the skid is removed, the merchandiser
must be lifted —NOT PUSHED— to reposition .
To remove the skid, remove screws attaching
skid to the merchandiser .
Check floor where cases are to be set to see if
it is a level area . Determine the highest part of
the floor .

MERCHANDISER LEVELING

B
e sure to position merchandisers
. Level the merchandiser by all four
properly
corners . Merchandiser(s) must be installed
level to ensure proper operation of the
refrigeration system and to ensure proper
drainage of defrost water .