Before Beginning Any Service Or Repair - Hussmann microSC MNGSC8-A Installation & Operation Manual

Medium temperature self contained island merchandisers
Table of Contents

Advertisement

P/N 3113125_A

Before Beginning Any Service or Repair:

Use a hand-held propane leak detector ("sniffer")
to ensure no propane is present in the immediate
area, the inside of the display case and the inside
of the refrigeration system . R-290 is an odorless
refrigerant . Keep the area clear of all customers
and non-essential or unauthorized personnel .
Verify that all repair parts are identical models
to the ones they are replacing . Do not substitute
parts such as motors, switches, relays, heaters,
compressors, power supplies or solenoids .
Failure to do so can result in an explosion,
death, injury and property damage . Parts
used on hydrocarbon cases must meet specific
UL certification for non-incendive or non-
sparking components . Use only Hussmann
approved parts approved through the Hussmann
Performance Parts Website .
hussmann .com/
Brazing must not begin before all propane has
been cleared from the immediate area — the
inside of the displays case and the inside of the
refrigeration system .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Figure C. Refrigeration Circuit #2 (right side)
https://parts .
Only Hussmann or factory
trained technicians should
service or repair this R-290
(propane) equipment.
Failure to follow
instructions can result in
an explosion, death, injury
and property damage.
Refrigeration lines are under pressure.
Refrigerant must be recovered before
attempting any connection or repair.