WASTE OUTLET AND WATER SEAL
These merchandisers have two waste outlets .
The condensate water outlet is located at each
end of the merchandiser . The outlet has a
factory installed, external water seal . For self-
contained models, this water seal may drain
into the condensate evaporator pan located
beneath the merchandiser, or directly to a floor
drain . The water seal is installed to prevent air
leakage and insect entrance .
For cases with evaporation pans:
Make sure the water level is similar in both
pans . During defrost cycle or off-time when the
compressor reaches setpoint, the water from the
evaporator goes to each evaporation pan .
NOTE: All lower base panels must be in place
when the refrigerator is operating . If not,
airflow from the condenser will be directed over
the evaporator pan and defrost water in the
pan may overflow .