MERCHANDISER ELECTRICAL DATA

Refer to the technical data sheets and
merchandiser serial plate for electrical
information .

FIELD WIRING

Field wiring must be sized for component
amperes stamped on the serial plate . Actual
ampere draw may be less than specified .
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES

ELECTRICAL CONNECTIONS

All wiring must be in compliance with NEC
and local codes .

ELECTRICAL OUTLET:

Before the merchandiser is connected to any
wall circuit, use a voltmeter to check that the
outlet is at 100% of the rated voltage . The wall
circuit must be dedicated for the merchandiser .
Failure to do so voids the warranty . Do not
use an extension cord . Never plug in more
than one merchandiser per electrical circuit .
• Always use a dedicated circuit with the
amperage stated on the unit .
• Plug into an outlet designed for the plug .
• Do not overload the circuit
• Do not use long or thin extension cords .
Never use adapters .
• If in doubt, call an electrician .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

ELECTRICAL / REFRIGERATION

NEMA 5-15P
Self-contained models have factory-installed
power cords attached at the electrical box . If
the power cord is damaged, it must be replaced
by personnel qualified for this task to prevent
hazardous situations .
Merchandiser must be grounded.
Do not remove the power sup
Risk of Electric Shock. If cord or plug
becomes damaged, replace only with
a cord and plug of the same type.
CONDENSATE PAN HEATER
(Optional)
A condensate pan heater is available as an
option . As a standard offering, there is no
heater installed in the condensate pan .
REFRIGERATION
(Self Contained Models)
Each self contained model is equipped with
its own condensing unit and control panel
located beneath the display area . The correct
type of refrigerant will be stamped on each
merchandiser's serial plate . The merchandiser
refrigeration piping is leak tested .
MNGSC8-A Self Contained Merchandisers
Plug
ply cord
ground.