Connections With A Controller; Wiring Connections With A Controller - Magnescale RU97-2048 Z Series Instruction Manual

Rotary magnescale
Table of Contents

Advertisement

Available languages

Available languages

7. Connections with a Controller

7-1. Wiring Connections with a Controller

Th is product and the controller that supports the SIEMENS DRIVE-CLiQ can be connected with CH22 or a cable made by
SIEMENS. Extension can be done up to a total length of 30m and a maximum of two cables.
CH22 or Extension connection cables
DRIVE-CLiQ connector
M12 8pol. molded
8
2
TX-P
7
TX-N
6
RX-P
3
RX-N
4
24 V
1
0 V
5
Connection Example 1
RU97
Connection Example 2
RU97
Extension connection cable
SIEMENS model no. 6FX8002-2DC34-
Extension connection cable
SIEMENS model no. 6FX8002-2DC30-
AS for the specifi cations of extension connection cables and purchasing of the cables, contact SIEMENS.
10
(E)
DRIVE-CLiQ connector
M12 8pol. molded
TX-P
TX-N
RX-P
RX-N
24 V
0 V
Shield
CH22-XXX SFF
or Extension
connection cables
Head Cable
30 m
Head Cable
30 m
CH22 or Extension connection cables
DRIVE-CLiQ connector
M12 8pol. molded
8
2
TX-P
7
TX-N
6
RX-P
3
RX-N
4
24 V
1
0 V
5
CH22-XXX SFY
or Extension
connection cables
CH22-XXX SFY
or Extension
connection cables
To the controller that supports
the SIEMENS DRIVE-CLiQ
DRIVE-CLiQ connector
RJ45 IP20 preassembled
RX-P
RX-N
TX-P
TX-N
24 V
0 V
Shield
The controller
that supports
the SIEMENS DRIVE-CLiQ
The controller
that supports
the SIEMENS DRIVE-CLiQ
RU97-2048 Z Series
3
6
1
2
A
B

Advertisement