Troubleshooting
REFRIGERATED CABINET FLOWCHART (CONTINUED)
Yes
Compressor Runs
No
Continuous?
Yes
42
Verify:
Compressor Overload Does Not Open
Start Components Function
Condenser Fan Motor Functions
Voltage Is Within 10% Of Nameplate
Clean The Condenser Coil
Restricted Clearances
High Ambient
Ice On Evaporator Coil Or Restricted Airflow
Check:
Temperature Set Too Low
Ice On Evaporator Coil
Low On Refrigerant
High Ambient
Restricted Clearances
Dirty Condenser Coil