Messages

14
Messages
14.1

Status messages

‰ An error code is displayed in the 7 segment display
41 in event of an error.
Code
Note
H08
Short-circuit
H30
Configuration
H34
Fans
Tab. 5:
Status messages
14.2

Error messages

‰ An error code is displayed in the 7 segment display
41 in event of an error. Press any button to display
the sub-error (Sub-Code).
Code
Error
E01
Excessive temperature
E02
Overvoltage
E04-1
Protective earth conductor
monitoring
E06
Overvoltage secondary
E07
EEPROM
E09
Voltage detection
E12
Power section
E13
Temperature sensor
E14
Supply voltage
E15
Current detection
E18
Overload protection
E22
Mains undervoltage
E25
Idle generator
E30
Error configuration
E31
Communications fault
E32
FPGA
E33
Power section
E34
Fans
E40
Polarity reverser
E41
Phase monitor
Tab. 6:
Error messages
11.18
i
Cause
Short-circuit in the output circuit
Component group recognition faulty
Fan current faulty
i
Cause
Duty cycle exceeded
Dust filter contaminated
Mains voltage too high
Fault current to protective earth con-
ductor
Initial voltage too high
Communication with EEPROM defec-
tive
Voltage measuring system faulty
Power section start-up faulty
Temperature sensor not ready for
operation
internal supply voltage too low
Error during current measurement
Safety switch device to protect elec-
trical components
Mains voltage on power unit is too
low
Idle generator faulty
Faulty or wrong pc-board, wrong
software system installed
CAN bus communication faulty
FPGA faulty
Power module not symmetrical
Fan current faulty
Polarity reverser faulty
Recognised missing mains phase
909.1550.1-08
After the message has been output, the
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
The status message can be deleted by
pressing the control knob 56.
Possible remedy
Eliminate the short-circuit (pick up
electrode holder, ...)
Inform Service
Inform Service
As long as there is an error code on display
welding is not possible.
Possible remedy
Allow switched-on machine to cool
down for a few minutes.
Replace dust filter
Check mains voltage
Connect the welding earth lead
Inform Service
Switch machine off and on again, ex-
ecute master reset
Inform Service
Inform Service
Inform Service
Check mains voltages
Inform Service
Inform Service
Check mains voltages
Inform Service
Inform Service
Switch the equipment off and on again
Inform Service
Inform Service
Inform Service
Inform Service
Check mains fuse and mains supply
- 19 -