Start-up
12.5

Special functions

Gouging
‰ Gouging is used for working out the roots or faulty
points and serves for preparing the weld seam.
‰ A special torch is required for gouging that has car-
bon electrodes and compressed air connection.
 Press and hold the electrode button 50 (Control Pro)
or 58 (Basic Plus) for at least 2 seconds.
9 The Electrode CEL LED 49 flashes.
 Set the desired current by rotating the control knob
56.
Up / Pulses (Control Pro)
‰ The Up and Pulses function can be activated or de-
activated. The Up (LED 37) and Pulses (LED 36)
functions are only available in an active state.
‰ If Up / Pulses is deactivated, the Arc Force can be
selected or deselected directly (without pressing but-
ton 30 several times).
Activate / deactivate Up / Pulses (Control Pro)
 Press button 55 to call up the secondary parameters.
 Select the Up / Pulses secondary parameter (Code
"PLS") by rotating the control knob 56.
 Confirm the secondary parameter by pressing the
control knob 56.
 Set the desired value by rotating the control knob 56.
– "On " = Activated
– "OFF" = Deactivated
 Confirm the setting by pressing the control knob 56.
 Exit the secondary parameters by pressing the Menu
button 55.
Switching Up on / off (Control Pro)
 Press button 30 until the Up symbol (LED 37) lights
up.
 Press button 55 to call up the secondary param-
eters.
 Select the Up frequency secondary parameter (Code
"uPF") by rotating the control knob 56.
 Confirm the secondary parameter by pressing the
control knob 56.
 Set the desired value by rotating the control knob
56.
 Confirm the setting by pressing the control knob 56.
 Repeat the operations for setting the Up second cur-
rent "uPI" and Up duty cycle "uPU" secondary pa-
rameters.
 Exit the secondary parameters by pressing the Menu
button 55.
11.18
The average welding current is displayed
i
Switching Pulses on / off (Control Pro)
 Press button 30 until the Pulses symbol (LED 36)
lights up.
 Press button 55 to call up the secondary param-
eters.
 Select the Second current I
(Code "I 2") by rotating the control knob 56.
 Confirm the secondary parameter by pressing the
control knob 56.
 Set the desired value by rotating the control knob
56.
 Confirm the setting by pressing the control knob 56.
 Repeat the operations to set the Pulse frequency
"FPU" and
eters.
 Exit the secondary parameters by pressing the Menu
button 55.
Hold functionality
‰ After the welding, with Hold = 5, 10 or On, the aver-
age values of the last welding task are visible in the
display for 5 sec., 10 sec. or permanently, the LED
for V (voltage) or A (amperage) is flashing. At Hold =
OFF the set-value of the welding current or the actual
welding voltage is shown in the display.
 Press button 55 to call up the secondary parameters.
 Select the Hold secondary parameter (Code "HOL")
by rotating the control knob 56.
 Confirm the secondary parameter by pressing the
control knob 56.
 Set the desired value by rotating the control knob 56.
– "OFF" = Deactivated
– „5 " = for 5 seconds the average values of the last
welding task are displayed
– „10 " = for 10 seconds the average values of the
last welding task are displayed
– „On " = Activated (permanently the average val-
ues of the last welding task are displayed)
‰ Pressing button 56 switches between actual value of
the welding voltage and welding current.
909.1550.1-08
and set in the 7 segment display. Welding
currents I1 and I2 deviate from the set val-
ue depending on the secondary parameter
settings "uPF", "uP1", "uP2" and "uPU".
The setting range of the average welding
current is 30 to 200 A
secondary parameter
2
"bPU" secondary param-
Pulse duty cycle
- 15 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X 350X 350 vrd ru

Table of Contents