Messages; Status Messages; Error Messages - LORCH MX 350 EU Operation Manual

Table of Contents

Advertisement

LORCH
14
Messages
14.1
Status messages
'--~~~~~~~~~-
0
An enror
code is
displayed
in
the
7-segment
display
in
the
event
of a
malfunction.
You can switch over
between error code and sub-error (sub
code)
in
the
7
segment display
by
pushing the button
44.
Code
Note
Cau
se
HOS
Short-circuit
Short-circuit in
the
output
circuit
Messages
After
the
message
has been
output,
the
machine will only
function
to
a
limited ex-
tent;
the
error
must
be corrected
as
quickly
as
possible.
The
status message can be
deleted
by
pressing the
control
knob
48.
PossJble remedy
Eliminate
the short-circuit
(pick
up
electrode holder,
...
)
H30
Configuration
Component gro up
recogniti
on
faulty
Inform
Service
H31
Communication
CAN bus
communication
faulty
Check
connected devices
and CAN
connections
H34
Fans
Fan current faulty
Inform
Service
Tab. 5:
Status
messages
14.2
Err
or
messages
0
An error
code
is
displayed
in
the
7-segment
display
in
the event of a
malfunction
.
You can
switch
over
between
error
code
and
sub-error
(sub code) in
the
7
segment
display
by pushing any
button.
CD
As
long as
there is an error code on
dis-
play
welding
is not
possible.
Code.
E11ror
Cause
Possible remedy
E01
Excessive
temperature
Duty
cycle exceeded
Allow switched-on
machine
to cool
down
for
a few
minutes
Dust filter
contami nated
Replace dust
filter
E02
Overvoltage
Mains
voltage too
high
Check
mains
voltage
E04-1
Protective
earth
conductor
Fault current to
protective
earth con-
Connect
the
welding earth
lead
monitoring
ductor
E06
Overvoltage secondary
Initial voltage too
high
Inform Service
E07
EEPROM
Communication w
ith
EEPROM
defec- Switch machine off and
on
again,
ex-
tive
ecute
master reset
E08-1
Excess motor voltage
Motor voltage too high
Inform Service
E08-2
Motor
power supply
Error
in
motor power
supply
Inform
Service
E08-3
Overcurrent on motor
Motor
current
cont
inuously
too high
Reduce motor
load
EOS-10
Torch
connection
Torch/torch
connection
error
Check torch and torch
connection.
Switch
the
equipment
off
and
on
again
E08-11
VII acquisition
Voltage/current measuring systems
Inform
Service
faulty
E09
Voltage
detection
Voltage measuring system faulty
Inform
Service
E12
Power
section
Power section
start-up fa
ulty
Inform Service
E13
Temperature
sensor
Temperature
sensor
not
ready
for
Inform Service
operation
E14
Supply
voltage
internal supply voltage
too
low
Check
mains voltages
E15
Current detection
Error
during current
measurement
Inform
Service
E18
I
Overload
protection
Safety switch
device
to protect
elec-
Inform Service
trical
components