Messages; Informative Messages - LORCH T BasicPlus Series Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26

Messages

Technical data*
Mains plug
Current input I1 no-load
Mains fuse slow-response TIG/EL
Phase angel cos φ I2 max
Powerfactor λ at I2 max
Max. permissible system impedance Zmax in acc.
with IEC 61000-3-11/-12
Recommended generator performance
Machine
Protection class
Insulation class
Cooling method
Noise emission
Norm
Designation
Dimensions and weights
Dimensions power source (LxWxH)
Weight of power source
Tab. 8:
Technical data
ED
= Switch-on duration
17
Messages
17.1

Informative messages

After the message has been output, the ma-
i i
chine will only function to a limited extent; the
error must be corrected as quickly as possible.
Code
Note
H01
Undervoltage
H03
Fans
H04
PFC
H05
EEProm checksum error
H06
EEProm write/read error
H10
Torch protection
Tab. 9:
Informative messages
01.21
Units
T 250 DC
BasicPlus
CEE 16
A
0,15
A
16
cos φ
0,97
λ
81
kVA
> 13 / 3 ~
IP
23S
B
F
db(A)
< 70
EN 60974-1
CE, S
mm
kg
14,3
*) measured at 40° C environmental temperature
Cause
Mains voltage too low
Fan fault
PFC faulty
Communication with EEProm faulty
Communication with EEProm faulty
Torch doesn't send ID although torch pro-
tection is activated
909.2669.9-02
Machine type
T 300 DC
T 250 AC/DC
BasicPlus
CEE 16
0,15
16
0,97
67
> 16 / 3 ~
23S
B
F
< 70
EN 60974-1
CE, S
430 x 185 x 326
14,5
Possible remedy
Check mains voltage
Inform Service
Inform Service
Switch machine off and on again, execute mas-
ter reset
Switch machine off and on again, execute mas-
ter reset
Adjust torch-ID
T 300 AC/DC
BasicPlus
BasicPlus
CEE 16
CEE 16
0,15
0,15
16
16
0,97
0,97
76
94
> 13 / 3 ~
> 16 / 3 ~
23S
23S
B
B
F
F
< 70
< 70
EN 60974-1
EN 60974-1
CE, S
CE, S
483 x 185 x 326
16,3
16,3
- 47 -