Technical Data - LORCH X Series Operation Manual

Table of Contents

Advertisement

17

Technical data

Technical data
TIG welding
Welding range min - max
Idle voltage (peak value in accordance
with EN 60974-1)
VRD (in accordance with
Idle voltage
ГОСТ 12.2 007.8)
Current setting
Slope characteristic
Welding current at ED 100%
Welding current at ED 60%
ED at maximum welding current
Current consumption I
(for ED 100%)
1
Current consumption I
(for ED 60%)
1
Current consumption I
max
1
Maximum effective mains current (I
Power consumption S
(for ED 100%)
1
Power consumption S
(for ED 60%)
1
Power consumption S
1 max
Electrode welding
Welding range min - max
Idle voltage (peak value in accordance
with EN 60974-1)
VRD (in accordance with
Idle voltage
ГОСТ 12.2 007.8)
Current setting
Slope characteristic
Welding current at ED 100%
Welding current at ED 60%
ED at maximum welding current
Current consumption I
(for ED 100%)
1
Current consumption I
(for ED 60%)
1
Current consumption I
max
1
Maximum effective mains current (I 1eff )
Power consumption S
(for ED 100%)
1
Power consumption S
(for ED 60%)
1
Power consumption S
max
1
Weldable electrodes
- 24 -
1)
10...350
A
V
10,4...24,0
< 113
V/DC
V/DC
Infinitely
variable
falling
A
250
A
300
%
40
12,3
A
15,7
A
19,6
A
12,4
)
A
1eff
8,5
kVA
kVA
10,9
kVA
13,6
A
10...350
20,4...34,0
V
V/DC
< 113
V/DC
Infinitely
variable
falling
230
A
280
A
35
%
A
16,0
A
20,7
A
27,5
A
16,3
11,1
kVA
14,3
kVA
19,1
kVA
1,5...8,0
mm
Technical data
MIG welding
Welding range min - max
Idle voltage (peak value in accordance
with EN 60974-1)
Mains
12
Mains voltage
Mains frequency
Positive mains tolerance
Negative mains tolerance
Negative mains tolerance, short-time
Mains connection
Mains plug
Current consumption I
Mains fuse slow-response TIG/EL
Power factor cos φ I
Max. permissible system impedance
Zmax in acc. with IEC 61000-3-11/-12
Recommended generator perform-
ance
Machine
Protection class
Insulation class
Cooling method
Noise emission
Standard
12
Designation
Dimensions and weights
Dimensions power source (LxWxH)
Weight of power source
Tab. 9:
Technical data
= Switch-on duration
ED
measured at 40°C ambient temperature
1)
909.1550.1-08
Technical data
1)
A
V
V/DC
V
Hz
%
%
%
mm²
A
1 no-load
A
max
cos φ
2
mΩ
kVA
IP
db(A)
mm
kg
1)
10...350
14,5...31,5
< 113
400 / 3~
50...60
25
30
40
4 x 2,5
CEE 32
0,2
25
0,99
44
34
F
F
<70
EN 60974-1
CE, S
515 x 185 x
400
18,6
11.18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X 350X 350 vrd ru

Table of Contents