Front panels

6.1
Front panel P-Synergic / S-Pulse / S-SpeedPulse 3.0
Fig. 4:
Front panel S 3.0
6.2

Front panel functions S/P

Gas test
– press the buttons "arrow up" [1] and "gas type" (+) [2] at the same time
– the gas valve is activated for 30 sec.
– a countdown is shown in the display
– press button "gas type" (+) [2] again to end the test manually
Pump / fan test
– press the buttons "arrow up" [1] and "material type" (-) [4] at the same time
– the cooling pump and the fans of the power unit are activated for one minute
– press button "material type" (-) [4] again to end the test manually
Reset
– press the buttons "arrow up" [1] and "TT Enter" [5] at the same time
– all secondary parameters are reset to their default values
– if Tiptronic is active, the settings of the current job are reset to their programmed values
– all adjustments of the Extras menu remain unchanged
- 12 -
on
power module temperature > 40°C
off
power module temperature < 40°C
on
after detection "arc established"
off
after welding two minutes post cooling-time
909.2710.1-06