Common Logic Functions

component
fan (power unit)
fan (power unit)
fan (cooling system)
fan (cooling system)
pump
pump
Gas test
- press the buttons
- the gas valve is activated for 30 sec.
- a countdown is shown in the display
- press button "gas type" (+) again to end the test manually
Pump test
- press the buttons
- the cooling pump is activated for one minute
- a countdown is shown in the display
- press button "material type" (-) again to end the test manually
Reset adjustments
- press the buttons
- all secondary parameters are reset to their default values
- if Tiptronic is active, the settings of the current job are reset to their programmed values
- all adjustments of the Extras menu remain unchanged
Master reset
- press the buttons
- the display shows "Master Reset"
- the machine is reset completely to factory settings
!!! CAUTION : all Tiptronic jobs are deleted !!!
function
on
off
on
off
on
off
(arrow up) and "gas type" (+) at the same time
(arrow up) and "material type" (-) at the same time
(arrow up) and "TT Enter" at the same time
(arrow up) and "Mode" together for about five sec.
associated event
power modul temperature over 40°C
power modul temperature below 40°C
after detection „welding current on"
after welding process, two minutes post-cooling time
after detection „welding current on"
after welding process, two minutes post-cooling time
5