CDA ECNK90 Installation, Use And Maintenance Manual

CDA ECNK90 Installation, Use And Maintenance Manual

Island extractor

Advertisement

Quick Links

ECNK90
Island Extractor
Installation, use and maintenance
www.cda.eu

Advertisement

Table of Contents
loading

Summary of Contents for CDA ECNK90

  • Page 1 ECNK90 Island Extractor Installation, use and maintenance www.cda.eu...
  • Page 2: Table Of Contents

    Contents: Important information Important safety warnings Using your extractor Care and maintenance Changing the charcoal filter Changing a light bulb (contact CDA Customer Care) Mains electricity connection Electrical information Troubleshooting Installation - preparation Ducting Installation Installation height diagrams Energy efficiency information...
  • Page 3 Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance Model...
  • Page 4: Important Information

    EU Declarations of Conformity: This appliance has been manufactured to the strictest standards and complies with all applicable legislation, including Gas safety, Electrical safety (LVD) and Electromagnetic interference compatibility (EMC). IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012/19/EU. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
  • Page 5 Please note: • Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system. • Do not vent the extractor into an attic or loft space. • Only house the extractor in rooms with adequate ventilation.
  • Page 6: Using Your Extractor

    Using your extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Fig. 1 Control Panel A - Power off button B - Speed level buttons C - Light button To switch the extractor light on or off...
  • Page 7: Care And Maintenance

    Care and maintenance IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. Cleaning Fig. 2 You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.
  • Page 8: Changing The Charcoal Filter

    (the same that holds the grease filter) so that it secures into place. Leave the tab on the filter accessible for when you need to remove it. Then, replace the grease filter. Charcoal filters are available as an optional accessory from CDA Customer Care under code CHA12.
  • Page 9 Changing the light IMPORTANT: THE LIGHT BULBS SHOULD ONLY BE CHANGED BY CDA AUTHORISED SERVICE AGENTS. IF ONE OR MORE OF YOUR BULBS FAIL, CONTACT CDA CUSTOMER CARE TO ARRANGE A SERVICE VISIT. DO NOT TOUCH THE LIGHT BULBS IMMEDIATELY AFTER USE AS THE BULB MAY BE WARM/HOT.
  • Page 10: Mains Electricity Connection

    Mains electricity connection DOUBLE POLE SWITCHED THIS APPLIANCE MUST BE FUSED SPUR OUTLET CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. USE A 3 AMP FUSE The appliance must be connected by a qualified electrician, who is a member of the N.I.C.E.I.C.
  • Page 11: Electrical Information

    NOTE: USE A 3A FUSE Assembly and electrical connection should be carried out by competent personnel. When installing this product we recommend you seek the help of another individual. Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation.
  • Page 12: Installation - Preparation

    Installation - preparation The extractor is intended to be mounted directly to a solid ceiling using fixings appropriate for the ceiling. When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor Gas: 750mm recommended.
  • Page 13: Ducting

    Ducting The ducting used should be 150mm, rigid circular pipe and must be manufactured from fire retardant material, produced to BS 476 or DIN 4102-B1. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The lengths of ducting with minimal effect on performance are as follows: •...
  • Page 14: Installation

    Installation ceiling Note • We recommend that you seek the Extractor height help of another individual when installing this product. Always wear adequate PPE (Personal Protective Equipment). B - clearance required • The fixings supplied are suitable Gas: 750mm recommended. for most installations.
  • Page 15 of the chimney section, use the calculation shown on this page for your extractor (also refer to fig 4): A = Height of gas hob burner or electric hotplate height from the kitchen floor B = Clearance required: 1 – lower struts 2 –...
  • Page 16 be at least the minimum height specified). Connect the mounting frame at the required height as per Figs. 10 and 11. 5. Place the chimney sections over the body assembly, as shown in fig 6. With the help of another individual, raise the whole assembly to the ceiling and fix securely in place using four screws appropriate for the wall plugs inserted in step 2.
  • Page 17 Fig. 10 Fig. 11...
  • Page 18 NOTES:...
  • Page 19: Energy Efficiency Information

    Sound power level 61.0 Grease Filter E ciency 81.3 (C) Hood c i f 110 (A) Hood E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
  • Page 20 For more information please contact: The Sales Department on 01949 862 010 or email sales@cda.eu Customer Care Department. The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY 01949 862 012 F: 01949 862 003 E: customer.care@cda.eu www.cda.eu...

Table of Contents