DTS 600 Elite Installation Manual page 11

Sliding gate motor with sl150 pcb
Table of Contents

Advertisement

4 – Lrn Master
• Follow the same steps as for Lrn Gate.
---------------------------------------------------------------------------------------------------
Remote Programming using Master Remote (Gate must be in the close position)
• Press the master remote button, buzzer will emit a continuous beep for 5 seconds.
• During that 5 seconds, press the new remote button. Continuous beep changes to rapid
beeps for 5 seconds.
• During that 5 seconds, press the same remote button again to validate the remote.
• Successful programming will be acknowledged by 2 or 3 beeps.
• If 3 x 100ms beeps are emitted on the pressing of the master remote, gate is not in the
close position.
• If 1 x 2 second beep emits on pressing the remote button, RX memory is full. (Max. 500)
• If 4 x 100ms beeps are emitted on pressing the remote button, remote is already in
memory.
• If new remote validation failed, rapid beeping will stop without the acknowledged 2 or 3
beeps being emitted.
---------------------------------------------------------------------------------------------------
5 – Delete
• Once you have pressed the ENT button.
• Press the transmitter button that you want to delete.
• The transmitter location will appear next to LOC=, EG LOC=4.
• Press the ENT button and that remote will show as delete.
• If the transmitter is not available but the number is known.
• Scroll down to LOC= and press ENT button.
• An arrow will appear next to LOC=.
• Use the UP or Down buttons to select the required transmitter button.
• Press the ENT button and scroll up to DELETE.
• Press the ENT button and that transmitter number will be indicated as deleted.
• Press ENT on MENU BACK to exit.
6 – Delete All (Master erase)
• Once you have pressed the ENT button.
• Scroll to select YES or NO and press the ENT button.
• If No was selected, the display will go back to Main Menu.
• If YES was selected, the system will delete ALL possible 500 transmitters.
------------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to RUN STATUS and press ENT. Screen will display:-
TR (Triggered by EG. transmitter.)
LS (Open or Close limit switch)
MAINS ON or OFF
BATT (Whatever the battery voltage is, EG 12.2V)
Press ENT to exit.
-------------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to GEN STATUS and press ENT. Screen will display:-
ER (Flashing Error number and Description of error)
OP (Number of Operations)
OL (Number of Overloads)
PU (Number of times unit was powered up)
Press ENT to exit.