DTS 600 Elite Installation Manual page 10

Sliding gate motor with sl150 pcb
Table of Contents

Advertisement

b) Pos Close, Gate will close hard on end stopper and release automatically in the
gearbox. (No movement will be visible on the gate)
• From desired selection, scroll down to MENU BACK and press ENT button three times.
c) LOAD=
• Press ENT button and an arrow will appear next to LOAD=.
• Select with UP or Down buttons the required % from Min. 20% to Max. 100%.
• Press ENT button on desired %.
d) COLL=
• Press ENT and an arrow will appear next to COLL=.
• Select with UP or Down buttons the required % from Min. 15% to Max. 100%.
• Press ENT button on desired %.
e) SBEAM NORM, SBEAM TEST
• Select either, No IR Beam, IRClose (normal w/o test), IR Close+T (with test before
closing), IR CL+OP (normal closing + opening beams) or IR CL+OP+T (closing + opening
beams with test)
• Scroll down to MENU BACK when selection was made.
• Press ENT button twice to exit.
2 - HI ACCESS or DOMESTIC
• Select Hi Access or Domestic by pressing the ENT button.
• Press ENT button to exit.
• Note: If High Access is selected then:- (PIRAC, CONDO & Auto close will be ON)
If Domestic is selected then: - (PIRAC, CONDO & Auto close will be OFF)
On both of the above - PIRAC, CONDO & Auto close can still be change as required.
3 - 100-400Kg or 400-700Kg or 700-1000Kg (Force requirement)
• Select the required Kg gate weight by pressing the ENT button.
• Press ENT button to exit.
-----------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to REMOTES and press ENT. Screen will display:-
LRN GATE, LRN PED, LRN RELAY, LRN MASTER, DELETE and DELETE ALL.
Select required function and press ENT button.
1 - Lrn Gate (Full open trigger)
Once you have pressed the ENT button.
Enter key P1 will appear with some blocks below the time out period to press and
release your transmitter button.
If the remote is successfully accepted, P2 will appear.
Press and release the transmitter button again.
The display will indicate which location the transmitter was saved in.
Press MENU with ENT button back to exit.
Should the display indicate Learn failed, Press on MENU BACK the ENT button and start
again.
2 – Lrn Ped (Pedestrian trigger)
• Follow the same steps as for LRN GATE.
3 – Lrn Relay (Will trigger item connected to relay output on PCB)
• Follow the same steps as for LRN GATE.
(Generally select HI ACCESS)
10
(Generally select, 400-700KG)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents