Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to
prevent the system from starting or spraying acci-
dentally. To reduce the risk of an injury from acci-
dental spray from the gun, splashing fluid, or
moving parts, follow the Pressure Relief Proce-
dure whenever you:
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray nozzle.
1. Fig. 4. Relieve the pressure of the entire system
following applicable system pressure relief proce-
dures. Ensure that system pressure is relieved
before proceeding with step 2.
2. Close hydraulic supply line shutoff valve (W).
3. Trigger the gun at the last gun station to relieve
fluid pressure. Maintain firm metal-to-metal contact
between the gun and a grounded waste pail.
Repeat for all gun stations.
4. Open the fluid drain valve (2) to relieve fluid pres-
sure which may be trapped in the pump, plumbing,
or hose.
10
310570
Operation
If you suspect that pressure is not fully relieved after
following the steps above, wrap a fitting near the pump
outlet with a rag, and slowly and carefully loosen the
fitting to relieve pressure. Be careful to protect your
eyes from splashing.
Packing Nut
Fig. 4. Before starting, fill the packing nut (AA) 1/3 full
with Graco Throat Seal Liquid (TSL) or compatible
solvent.
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
The packing nut is torqued at the factory and is ready
for operation. If it becomes loose and there is leaking
from the throat packings, relieve pressure, then torque
the nut to 34–40 NSm (25–30 ft-lb). Do this whenever
necessary. Do not overtighten the packing nut.
Flush the Circulation Package Before First
Use
The circulation package is tested with lightweight oil,
which is left in to protect the circulation package parts.
If the fluid you are using may be contaminated by the
oil, flush it out with a compatible solvent. See Flush-
ing on page 13.