Piping And Drain Hose Installation; Piping And Drain Hose Forming; Die-Cutting Back Body Slit; Changing Drain Hose - Toshiba RAS-18J2KVSG-E Service Manual

Indoor/outdoor unit, r32 inverter
Hide thumbs Also See for RAS-18J2KVSG-E:
Table of Contents

Advertisement

5.
Fix control wire which arrange as shown on figure 6 and 7 to
terminal by provided screws (tighten firmly but not over 0.25 N·m
(0.03 kgf·m)).
6.
Set control wire through gutter way at rear side of remote controller
as shown on f gure 8.
7.
Fix provided screw (Ø3.1×16L) on the wall to hang remote
controller as shown on figure 9.
8.
Mark and arrange hole for fix below screw (Ø3.1×25L) as
shown on figure 9.
9.
Assembly battery cover which provided with accessory bag then
use provide screw (Ø3.1×25L) to fix battery cover together with
wall as shown on figure ! (tighten firmly but not over 0.15
N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
4
5
1.5V
1.5V
Control wire
Plastic for cover hole
7
Control wire
1.5V
1.5V
Terminal
Wire and hole for fix screw should be have space to prevent
wire damage during close by battery cover.
Hole for hang
remote controller
Control wire
Remote controller
Remote controller
8
Battery cover
*Remark : 1. Recommend to use double insulation lead wire for
connect remote control and air conditioner.
2.
For wire operation, 1 remote control can control
only 1 indoor unit
3.
In wire operation, remote controller will return to
initial condition (PRESET, TIMER and CLOCK will
return to initial condition) when user shutdown
power supply of air conditioner.
6
30 mm
5 mm
20 mm
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for fi x battery cover
9
!
Screw
Tighten fi rmly but not over
0.15 N·m (0.02 kgf·m)

10-3-4. Piping and drain hose installation

<Piping and Drain Hose Forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right

1. Die-cutting back body slit

Cut out the slit on the leftward or right side of the back
body for the left or right connection and the slit on the
bottom left or right side of the back body for the bottom
left or right connection with a pair of nippers.

2. Changing drain hose

For leftward connection, bottom-leftward connection
and rear leftward connection's piping, it is necessary to
change the drain hose and drain cap.
<How to remove the Drain Cap>
Clip the drain cap by needle-nose pliers and pull out.
<How to remove the drain hose>
The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
To install the drain hose, insert the drain hose firmly
until the connection part contacts with heat insulator,
and the secure it with original screw.
Drain hose
Fig. 10-3-8
- 75 -
Fig. 10-3-6
Fig. 10-3-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents