<When the installation plate is directly mounted on
the wall>
1. Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook up
the indoor unit.
2. To mount the installation plate on a concrete wall
with anchor bolts, utilize the anchor bolt holes as
illustrated in the above figure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a
mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in
personal injury and property damage.
Installation plate
<Keep horizontal direction>
Fig. 10-3-4
5 mm dia. hole
Clip anchor
(local parts)
Fig. 10-3-5
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting
screws .
6
NOTE:
• Secure four corners and lower parts of the
installation plate with 4 to 6 mounting screws to
install it.
Anchor
bolt
Projection
15 mm or less
Mounting
6
screw
∅4mm x 25 s s s s s
- 74 -
10-3-3. How to Connect Remote Controller for
Wire Operation
< For indoor unit >
1.
Open two screw cap and securely remove two screws at
the front panel.
2.
Slightly open the lower part of the front panel then pull the
upper part of the front panel toward you to remove it as
shown on figure
.
1
3.
Arrange the control wire as detail and specification as
shown on figure
.
2
4.
Securely connect the control wire to terminal of Display unit
as shown on figure
.
3
(tighten firmly but not over 0.12 N·m (0.01 kgf·m)).
Set the control wire out from indoor unit same portion as
5.
power supply and connecting cable as shown on figure
(Notch for wire out)
6.
Reassembly the indoor unit by reverse process of 1 to 2.
1
Screw
* Wire size 28-22AWG
or 0.08-0.32 mm
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
3
Control wire
< For remote controller >
1.
Remove cover of remote controller by sliding down and take it out.
If batteries are exist, please take them out. The combination of
2.
using wire controller and batteries may cause of batteries
explosion.
Make hole for insert control wire by use screwdriver break the
3.
polyester sheet as shown on figure 4.
4.
Insert control wire from rear side of remote controller as shown on
figure 5.
Indoor unit
Control wire
Remote controller
Front panel
Screw
Screw cap
2
70 mm
2
5 mm
Notch for wire out
Control wire
Terminal
.
3
Display unit