Toshiba RAS-18J2KVSG-E Service Manual page 118

Indoor/outdoor unit, r32 inverter
Hide thumbs Also See for RAS-18J2KVSG-E:
Table of Contents

Advertisement

1) Follow the procedure item
8
Drain pan
2) Remove screw holding the electric part
assembly
3) Disconnect the louver motor connector (5P)
4) Disconnect the cord motor of Louver VT (5P)
5) Disconnect the cord motor of Louver motor
6) Remove fixing screw of the unit display
7) Remove drain pan can be selected remove
<To re-installation>
- Press the drain pan into the back body.
- Please make sure ribs of drain pan in left
- Press the two center arms of drain pan to back
cover.
from P.C. board assembly.
from the Louver VT (L/R) connector.
(L) (5P) from the Louver motor (L) connector.
L
N
1
2
Louver motor (L)
connector (blue)
(blue)
(black)
Louver motor VT (L)
connector (white)
Louver motor VT (R)
connector (black)
and remove unit display.
drain hose or not remove drain hose following:
- Not remove drain hose;
Pulling out the drain pan from back body,
then holding the drain pan with main unit.
- Remove drain hose;
Drain hose can be removed follow the
procedure item 7 . After that remove the
drain pan from main unit.
and right side must be install to lock position.
body.
Back body
Rib of drain pan
Drain pan
Back body
3
.
3
P.C.board
Louver motor
connector
Louver motor connector
Drain pan
Center arms
of drain pan
- 118 -
Remarks
Screw
Electric part cover
Unit display
Screw
Drain pan
Back body
Rib of drain pan
Drain pan
Connectors

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents