Quiet Mode; Short Timer - Toshiba RAS-18J2KVSG-E Service Manual

Indoor/outdoor unit, r32 inverter
Hide thumbs Also See for RAS-18J2KVSG-E:
Table of Contents

Advertisement

Item
17. QUIET
The "Quiet mode" selected from [ FAN ] button;
Mode
- The fan of the indoor unit will be restricted the
revolving speed at speed UL.
- The compressor speed is controlled as shown in
the figure.
Model
Cool min (Hz)
Quiet Cool (Hz)
Heat min (Hz)
Quiet Heat (Hz)
The "Quiet mode" is canceled by [ FAN ] button is
pressed to select other speed.

18. Short Timer

In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
Operation flow and applicable data, etc.
18k
19.2
44.4
19.2
55.2
4
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
Remarks :
1. Quiet mode is unable to work in dry mode.
22k
24k
2. Quiet mode is appropriate to work with less
19.2
19.2
cooling load condition.
44.4
44.4
Because of the fan speed L- may cause not
19.2
19.2
enough the cooling capacity capacity.
55.2
55.2
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
1
Press [
2
Set the operation mode
on the remote control without
sending the signal to the unit.
3
Use the tip of the pencil to push the
[CHECK] button and hold, "00" will
show on display, them press [SET]
button to make "00" disappear.
4
Press [
5
When short timer is activated, all
setting on the remote operates
immediately, besides, all indicatiors
on front panel turns ON continuously
for 3 seconds.
3
- 52 -
Description
] button to turn the unit OFF.
] button to turn the unit ON.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents