Sony CDU-541 Interface Manual page 89

Table of Contents

Advertisement

CDU-541 CD-ROM DRIVE SCSI INTERFACE MANUAL
specified and CD-ROM mode two data is detected the read operation will be
terminated with a CHECK CONDITION status.
The sense key will be set to
ILLEGAL MODE FOR THIS TRACK.
Table 5-35: Error Recovery Procedures - CD-ROM Mode One Data
==============================================================================
Error Recovery Description
------------------------------------------------------------------------------
OOh This is the default setting of the error recovery parameter on when a
power-on or reset condition occurs.
The maximum error recovery
procedures are used.
Only L-EC uncorrectable data errors are reported.
If an L-EC uncorrectable data error occurs data transfer is terminated
with a CHECK CONDITION status.
The sense key is set to MEDIUM ERROR and
the additional sense code is set to L-EC UNCORRECTABLE DATA ERROR.
The
information bytes are set to the address of the last block transferred to
the initiator plus one.
04h The maximum error recovery procedures are used.
L-EC recovered data
errors are reported.
If an L-EC recovered data error occurs data
transfer is not terminated.
However, when the data transfer has
completed a CHECK CONDITION status is reported.
The sense key is set to
RECOVERED ERROR and the additional sense code is set to L-EC RECOVERED
DATA ERROR.
The information bytes are set to the address of the last
block for which an L-EC recovered data error was detected.
-
If an L-EC uncorrectable data error occurs data transfer is not
terminated.
However, when the data transfer has completed a CHECK
CONDITION status is reported.
The sense key is set to MEDIUM ERROR and
the additional sense code is set to L-EC UNCORRECTABLE DATA ERROR.
The
information bytes are set to the address of the last block on which an
.,-..../
L-EC uncorrectable error was detected.
06h The maximum error recovery procedures are used.
L-EC recovered data
errors are reported.
If an L-EC recovered data error occurs data
transfer is terminated with a CHECK CONDITION status.
The sense key is
set to RECOVERED ERROR and the additional sense code is set to L-EC
RECOVERED DATA ERROR. The information bytes are set to the address of the
last block transferred to the initiator plus one.
If an L-EC uncorrectable data error occurs data transfer is terminated
with a CHECK CONDITION status.
The sense key is set to MEDIUM ERROR and
the additional sense code is set to L-EC UNCORRECTABLE DATA ERROR.
The
information bytes are set to the address of the first block on which an
L-EC uncorrectable error was detected.
==============================================================================