1-1. Installation Environment

Operating temperature : 5 dC to 40 dC
_20 dC to +55 dC
Storage temperature :
Operating humidity :
20 % to 90 %
(non-condensing)
Do not install the BDX-N1000 in the following locations.
. Areas where the unit will be exposed to direct sun light
or any other strong lights.
. Areas near heat sources.
. Dusty areas or areas where it is subject to vibration.
. Areas with strong electric or magnetic fields.
. Areas where is subjected to electricity noise.
. Areas where is subjected to static electricity noise.
To prevent the temperature rise inside the BDX-N1000,
pay careful attention to circulation of air in the place where
the BDX-N1000 is installed.
The rear side of the BDX-N1000 should be at least 20 cm
(8 inches) away from walls for ventilation and
maintenance.
c
Do not block the ventilation holes.
If the ventilation holes are blocked, the temperature inside
the BDX-N1000 getting rise. This may cause a fire.

1-2. Power Supply

1-2-1. Power Specifications

Power requirements : 100 to 240 V AC
50/60 Hz
Current consumption : maximum 0.5 A (at 100 V)
maximum 0.3 A (at 240 V)
A switching regulator is used for the power supply of the
BDX-N1000. The voltage within the range of 100 V to
240 V can be used without changing the supply voltage.
n
As the inrush current at turn-on is maximum 45 A (at
100 V)/maximum 90 A (at 240 V), the capacity of the AC
power must be adequate with the inrush current of maxi-
mum 45 A (at 100 V)/maximum 90 A (at 240 V).
If the capacity of the AC power is not the adequately large,
the breaker of the AC power at the supply side will operate
or the BDX-N1000 will abnormal operate.
BDX-N1000
Section 1

Installation

1-2-2. Power Cord

w
. Use the specified power cord. If the power cord that is not
specified is used, it may cause a fire or an electric shock.
. Do not damage the power cord. If the power cord is
damaged, it may cause a fire or an electric shock.
Power cord for the customer in the U.S.A. and Canada.
1 Power cord set
2 Plug holder (Black)
For customers in European countries except the United Kingdom
1 Power cord, 250 V 10 A (2.4 m) : ! 1-551-631-15
2 Plug holder (Brown) :
1
For customers in the United Kingdom
1 Power cord, 250 V 10 A (2.4 m) : ! 1-782-165-11
2 Plug holder (Brown) :
1
n
For the customer outside of the area as shown above or in a
part of Europe, the above-mentioned power cords con not
be used.
Use the power cord that is applicable to the places in the
world.
! 1-557-377-41
2-990-242-01
1
2
AC inlet
3-613-640-01
2
3-613-640-01
2
AC inlet
AC inlet
1-1 (E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bdkp-n1001Bdkp-n1002Bdkp-n1003Bdkp-n1004

Table of Contents