Eclipse TFB030 Installation Manual page 8

Eclipse tube firing
Hide thumbs Also See for TFB030:
Table of Contents

Advertisement

Table 3.2 Dimension A Inches (mm) for TFB075
Fuel
Natural Gas
Propane
Butane
Table 3.3 Dimension A Inches (mm) for TFB200
Fuel
751k-800k
Natural Gas
0.500 (12.7)
Propane
0.374 (9.5)
Butane
0.251 (6.4)
Fuel
1401k-
1500k
Natural Gas
0.625 (15.9)
Propane
0.500 (12.7)
Butane
0.374 (9.5)
Adjust the Nozzle
NOTE: Place burner on a suitable working surface.
1. Remove the spark rod (3) or (3a) and flame rod (3) if
applicable.
2. Remove the four washers and bolts (1).
3. Pull the rear cover (2) far enough away from the
housing (4) to get access to the lock nut (5).
4. Loosen the lock nut (5).
5. Push the assembly back together.
6. Hold the rear cover (2) in position and screw the
nozzle in or out to adjust dimension A. See Figure 3.1.
7. Carefully pull the rear cover (2) and nozzle assembly
out of the housing (4).
Figure 3.2. Disassemble the Burner
8
301k-350k
351k-400k
0.374 (9.5)
0.500 (12.7)
0.251 (6.4)
0.374 (9.5)
0.125 (3.2)
0.251 (6.4)
801k-900k
901k-1000k
0.500 (12.7)
0.500 (12.7)
0.374 (9.5)
0.374 (9.5)
0.251 (6.4)
0.251 (6.4)
1501k-
1601k-
1600k
1700k
0.625 (15.9)
0.625 (15.9)
0.500 (12.7)
0.500 (12.7)
0.374 (9.5)
0.374 (9.5)
3a
Spark rod location if
flame rod is used.
401k-500k
501k-600k
0.500 (12.7)
0.625 (15.9)
0.374 (9.5)
0.500 (12.7)
0.251 (6.4)
0.374 (9.5)
1001k-
1101k-
1100k
1200k
0.625 (15.9)
0.625 (15.9)
0.500 (12.7)
0.500 (12.7)
0.374 (9.5)
0.374 (9.5)
1701k-
1801k-
1800k
1900k
0.625 (15.9)
0.625 (15.9)
0.500 (12.7)
0.500 (12.7)
0.374 (9.5)
0.374 (9.5)
Figure 3.3. Adjust the Nozzle
8. Turn the nozzle (6) over the shortest distance until the
opening (7) in the nozzle for the spark rod (3) aligns
with the appropriate opening in the rear cover (2).
9. Make sure that the nozzle (6) does not move and
tighten the lock nut (5).
10. Reinstall spark rod (3) or (3a) and flame rod (3) if
used.
5/8" (16 mm)
Figure 3.4. Position the Spark Rod &
Flame Rod (if used)
Eclipse TFB, V2, Installation Guide 310, 11/14/2014
601k-750k
0.625 (15.9)
0.500 (12.7)
0.374 (9.5)
1201k-
1301k-
1300k
1400k
0.625 (15.9)
0.625 (15.9)
0.500 (12.7)
0.500 (12.7)
0.374 (9.5)
0.374 (9.5)
1901k-
2000k
0.625 (15.9)
0.500 (12.7)
0.374 (9.5)
Spark rod location if
3a
flame rod is used

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tfb075Tfb200

Table of Contents