8.1 Alarm 1: Power outage
When a power outage occurs during the work phase of the stove, there are two ways the stove may react.
If the period without power is shorter than the one set in the technician settings, the stove will continue with
the working phase once the power is on again.
If the period without power exceeds the pre-set limit, the stove will trigger alarm 1.
8.2 Alarm 2: Smoke temperature sensor failure
This alarm is triggered in case of a faulty smoke temperature sensor.
8.3 Alarm 3: Overheating
This alarm is triggered if the measured smoke temperature is beyond a certain value.
8.4 Alarm 4: Exhaust fan failure
This alarm is triggered in case of a faulty exhaust fan.
8.5 Alarm 5: Ignition failure
This alarm is triggered if the ignition phase fails, meaning that the minimum smoke temperature has not been
reached during the ignition phase.
8.6 Alarm 6: No pellets
This alarm is triggered if the smoke temperature falls below the minimum smoke temperature needed during
the work phase.
This alarm can also happen due to jamming of pellets of inadequate
dimensions.
8.7 Alarm 7: Thermal safety overheating
This alarm is triggered if the safety thermostat detects a temperature beyond 100°C.
8.8 Alarm 8: No negative pressure
This alarm is triggered if the external pressure sensor detects a pressure value below the pre-set limit.