U-Line CLR60 User Manual page 31

Clear ice machine
Table of Contents

Advertisement

Problem
Unit runs but
produces very
little ice
(continued)
Ice is slow to
release or does
not release from
the evaporator
Poor ice quality
(soft or unclear)
Unit produces
shallow or
incomplete cubes,
or the ice fill
pattern on the
evaporator is
incomplete
Possible Cause
Inadequate airflow at
the front of the unit
Ice thickness
adjustment dial
improperly set
Ice-making system
is dirty
Unit is not level
Low air temperature
around unit
Poor incoming water
quality
Ice-making system is
dirty
Low water level
Hot incoming water
Ice thickness
adjustment dial
improperly set
Incorrect incoming
water pressure
Unit is not level
29
Remedy
Remove items blocking
airflow
Adjust ice thickness.
See ADJUSTING ICE
THICKNESS
Run unit through
automatic clean cycle.
See CARE AND
CLEANING
See LEVELING THE UNIT
Surrounding air
temperature must be
at least 50°F (10°C)
Consult a qualified
plumber to test the
water quality and
recommend appropriate
treatment
Run unit through
automatic clean cycle.
See CARE AND
CLEANING
Check to see that
overflow tube is fully
seated
Connect the unit to a
cold water supply.
See INSTALLATION
Adjust ice thickness.
See ADJUSTING ICE
THICKNESS
Water pressure must
be 20-120 psi
See LEVELING THE
UNIT