Download Print this page

IBM 7036-P16 Manual page 6

Lan attached remote asynchronous node (ran)

Advertisement

digiasync.realport.obj
digiasync.realport.obj
If there is any other response, then the Digi RealPort® Software is not installed and the user should go to the
Procedure.
3. Type: smitty devices.
4. Use the cursor to select: Digi Device and Terminal Servers and press Enter.
5. Use the cursor to select: Add a Digi Device and Terminal Servers and press Enter.
6. Use the cursor to select: cts_16 and press Enter.
7. Move the cursor to the IP address box and type: [IP address] and press Enter. This is the IP address of the target 7036-
P16 used in 1.
When the command is entered, the user should see the following on the screen: Command: OK stdout: yes stderr: no
Note: Additional instructions might appear before the command is completed. Perform any instructions if needed. For
example, sa[device number] Available
8. Press F10 to exit from smitty. This concludes the device configuration portion of this process. Once the serial device is
configured, the tty ports need to be configured. Go to
7036-P16 Serial port TTY configuration on an AIX host server.
This procedure assumes the target 7036-P16 and the server are configured, attached to the network and the Digi RealPort® software is
installed on the server.
1. Ensure the 7036-P16 and the server are on the network. The user should ping the 7036-P16 by typing the following
command: ping -c 1 [IP address of target 7036-P16]. If the 7036-P16 responds to the ping, then it is on the network, go
to 2.
If the 7036-P16 does not respond to the ping, then the 7036-P16 is not on the network and the user must go to
Network Configuration
2. Insure the Digi RealPort® Software is installed on the server. Type the following command lslpp -l | grep digi
and press Enter.
The response should be: digiasync.realport.obj 3.8.0.0 Committed Digi RealPort Driver digiasync.realport.obj 3.8.0.0
Committed Digi RealPort Driver. If there is any other response, then the Digi RealPort® Software is not installed and the
user should go to the
3. Type: smitty devices.
4. Use the cursor to select: Add a TTY and press Enter.
5. Use the cursor to select: tty rs232 Asynchronous Terminal
6. Use the cursor to select: sa[device number] Available Digi PortServer TS 16 and press Enter.
7. Enter a port number not already assigned to a tty, for example 1, and press Enter. Upon successful completion of this
command the user should see the following on the screen:
Command: OK stdout: yes stderr: no
Before command completion, additional instructions may appear. tty[number available]
Note: The [number] is the number assigned by smitty as the next available tty device.
8. Press F10 to exit from smitty.
This concludes the serial port tty configuration on an AIX server.
Configuring the 7036-P16 as a TTY device on a Linux host server
3.8.0.0
3.8.0.0
procedure to perform the network configuration.
AIX Installation
Procedure.
Committed
Digi RealPort Driver
Committed
Digi RealPort Driver
7036-P16 Serial port TTY configuration on an AIX host server.
AIX Installation
the7036-P16

Advertisement

loading