Lan attached remote asynchronous node (ran)

Advertisement

The 7036-P16 supports full-duplex operation up to 230K bps for any one port running, with the other fifteen ports running at
speeds not to exceed 115K bps. Operation with all sixteen ports running full-duplex at 115K bps is supported.
Network Throughput:
The 7036-P16 is an Ethernet attached device and as such any number may be attached to given network. However, the user
must realize that attaching more devices to any network reduces the overall network throughput and care must be taken to not
overload any given network.
Testing has shown that as many as eight 7036-P16 devices may be attached to a network without adversely affecting network
throughput. More devices may be attached, but network performance may be adversely affected.
Server Throughput:
Each 7036-P16 provides 16-Ports of asynchronous EIA-232 connectivity over a 10/100 Ethernet port at speeds up to 128 K
bps. Given that any number of 7036-P16 may be attached to a server, a single server, or server partition could in effect have a
large number of asynchronous EIA-232 connections. The user is cautioned that increasing the number of asynchronous EIA-
232 connections beyond 128 is not recommended.
7036-P16 Hardware installation instructions
Install the 7036-P16 as a rack device.
Install the 7036-P16 as a desk top device.
Package contents:
7036-P16
7036-P16 Software and Documentation CD.
7036-P16 Quick Setup Guide.
Brackets to mount 7036-P16 on rack.
Rubber feet for table top usage.
Power cord (North American 120 VAC use only).
RJ45 to DB25 Serial Cable (DB25 wired per EIA-232 Specification).
RJ45 to DB09 Serial Cable (DB09 matches pin configuration on existing DB09 serial ports on pServers).
RJ45 Wrap Plug for Diagnostics.
Tools:
Phillips Head Screwdriver
Desk top installation procedure:
1. Unpack hardware.
2. Remove the rubber feet from the packaging.
3. Attach the rubber feet to the bottom of the 7036-P16 in the spots indicated.
4. Attach the power cord. A power cord for use in North America is provided.
5. Use an Ethernet cable to connect the 7036-P16 to the network.
6. Connect serial devices as needed.
Rack mount installation procedure:
1. Unpack hardware.
2. Remove the right angle brackets and screws from the packaging.
3. Use a Phillips head screw to attach the brackets in the pre-drilled holes on the sides of the 7036-P16.
4. Attach the power cord. A power cord for use in North America is provided. Attach the power cord. A power cord for use with
120 VAC is provided. Optional rack power cord feature codes (FC) are available to connect the 7036-P16 to the rack Power
Distribution Unit (PDU). These come in various lengths and may be purchased from IBM as the following features codes:
FC 6458: Power Cord (14-foot), Drawer to IBM PDU, 250V/10A.
o
FC 6672: Power Cord (9-foot), Drawer to IBM PDU, 250V/10A
o
FC 6671: Power Cord (5-foot), Drawer to IBM PDU, 250V/10A (Only available for use in racks less than 25U)
o
5. Use an Ethernet cable to connect the 7036-P16 to the network.
6. Connect serial devices as needed.