P RIMARY
INTERLOCK
NC
NO
C-10
J5
J11
A18-TOP BLOWER 0-10 VDC/RED
J10
A17- BOT BLOWER 0-10 VDC/RED
A9- RTD-1 INPUT/ORANGE
A8- RTD-2 INPUT/ORANGE
C ARD
A7-RTD-3 INPUT/RED
A5-VOLTAGE MODULE GROUND/BLACK
B17-K1-A (+24 VDC OUTPUT)/RED
A (20 PIN)
B16-K8-B(STIRRER)/WHITE
B10-BOT BMSC STATUS (J1-5)/GRAY
11
20
1
10
B8-BOT BMSC GND (J1-2 &4)/BLACK
B7-TOP BMSC GND (J2-2 &4)/BLACK
12
24
B2-BOT BLOWER ENABLE (J1-3)/WHITE
B1-TOP BLOWER ENABLE (J2-3)/WHITE
C22-K5-B4 (HEATER)/WHITE
B (24 PIN)
C21-K4-A2 (HEATER)/WHITE
C20- SPEAKER (+)/RED
1
C19- +24 VDC INPUT/RED
C17-MAG OT +24VDC/RED
1
13
C16- K7-B (MAGNETRON FANS)/WHITE
1
11
C14-K2-B (MAGNETRONS)/WHITE
22
C13- K1-B (FILAMENT TRANSFORMERS)/WHITE
12
C (22 PIN)
C12-K2-A (MAG-OT) STATUS/WHITE
C11- K3-B (MONITOR STATUS)/ORANGE
C10- CDP-N.O STATUS/WHITE
C9-CDS-N.O STATUS/WHITE
C8-24 VDC (-) INPUT/BLACK
C7- SPEAKER GROUND/BLACK
C6- CDP-C (GROUND)/BLACK
C5- CDM-C & CDS-C (GROUND)/BLACK
C4- K6-B (VOLTAGE SELECTOR)/WHITE
C3- (VOLTAGE SELECTOR INPUT)/RED
C1- TOP BMSC STATUS/GRAY
J8
J7
J4
TURBOCHEF TECHNICAL SUPPORT
800-908-8726 (USA)
+214-379-6000 (International)
DELTA
LOAD
L2
DIAGRAM
HX2-2
F3-1
MW1 CT
L3
L1
EMI FILTER
MW2 CT
50A
AYA6A
230VAC, 3Ø
4 WIRE INPUT
BRN
BLK
BLK
GRN
Figure 34: i5 Oven Schematic
QC4
1
2
OT2
SAFETY INTERLOCKS
FAN2 (COOLING/REAR)
C
NO
MONITOR
SWITCH
NC
120°F
C
C
NO
(49°C)
NC
C
NO
S ECONDARY
QC5
INTERLOCK
1
2
C-6
C-11
FAN1 (COOLING/COMPARTMENT)
C-5
C-9
SPEAKER
QC5
C -20
1
C -7
2
J2
J5
RED
1
Analog Speed 0-10V
A-18 (RED)
2 40 VAC
1
BLACK
B-7 (BLACK)
3 PHASE
I/O COMMON
2
2
WHITE
OUT
ENABLE
3
B-1 (WHITE)
BLWR
3
GREEN
I/O COM
4
B-7 (BLACK)
MTR
4
TOP
STATUS OK
5
C-1 (GRAY)
(CCW)
GND
I/O COMMON
6
1
0-10V
A-17(RED)
BLACK
1
2
I/O COMMON
B-8 (BLACK)
RED
2 40 VAC
2
ENABLE
3
B-2 (WHITE)
WHITE
3 PHASE
BLWR
3
OUT
I/O COM
4
B-8 (BLACK)
MTR
GREEN
4
STATUS OK
5
B-10 (GRAY)
BOTTOM
(CW)
J4
I/O COMMON
6
GND
J1
BMSC
J3
1
180-240
2
VAC IN
3
C -19
+V
24VDC
N
POWER
C -5
-V
SUPPLY
L
G
2
2
NOTE: NOT CONNECTED FOR
INTERNATIONAL MARKETS
F1
F2
QC10
1
VOLTAGE
1
E1(BLACK)
C -3
1
E4
2
E2 (RED)
A -5
2
E3
MODULE
WYE
L2
K6-7
LOAD
K3-7
DIAGRAM
HX1-2
HX2-2
JUMPER ONLY FOR
N
SINGLE PHASE
L1
L3
EMI FILTER
50A
EMI FILTER
50A
AYA6A
AYA6A
L3
L2
380-415, 3Ø
N
L1
5 WIRE INPUT
BLK
GRAY
BRN
BLU
GRN
K8 (STIRRER)
1
QC3
7
4
1
3
9
2
6
A
B
STIRRER
B-16
K7 (FANS)
1
7
4
NOTE: ALL 50 HZ OVENS HAVE 230VAC TRANSFORMERS( TAPS 1-2 ARE CONNECTED)
3
9
6
A
B
C-16
(C)
K6 (VOLTS)
1
(240)
7
(208)
4
(208)
2
(240)
(240)
8
MAG
5
(208)
CT
S PLICE 1
3
(240)
HV TRANSFORMERS
6
(208)
9
(C)
A
B
C-4
(208)
K3 (MONITOR)
(240)
1
7
4
3
9
6
A
B
(C)
C-11
(208)
K2 ANODE
(240)
1
7
4
3
9
6
(C)
A
B
(208)
C-14
(240)
K1 (FILAMENT)
1
7
C-12
4
2.2K 1/2W
3
9
6
2
2
A
B
F3
F4
32
C-13
1
1
1
B-17
C-21
MANUAL RESET
C-22
F1: 12 AMPS CLASS CC
F2: 12 AMPS CLASS CC
F3: 12 AMPS CLASS CC
FOR UK VERSION,
F4: 12 AMPS CLASS CC
SUBSTITUTE IEC 3-PIN PLUG
i5-XXXX
D ASH
N EXT ASSY
NO
APPLICATION
DWG NO
SH
i5-9100
1
REVISIONS
LTR
DESCRIPTION
DATE
A
RELEASE FOR PRODUCTION
11/20-2007
JUMPER FOR 50 HZ OPERATION ONLY (BETWEEN PIN 1&3)
2
3
1
MAG
T1
(-) D1 (+)
. 19UF
. 91UF
C1
FAN 1
QC6
C2
2
3
1
. 19UF
. 91UF
MAG
(-) D2 (+)
FAN 2
T2
QC7
MAGNETRON OVERTEMP
MAG 1
MAG 2
212°F (100°C)
212°F (100°C)
OT3
OT4
C
C
FT1
NC
NC
K8
QC1
QC2
K7
FT2
K6
(QC9 RTD)
K3
A-9
A-8
RELAY ASSY
A-7
31
22
21
K2
1
12
11
1
HX 1 (3000W/14.4 OHMS)
OT1
HX 2 (3000 W/14.4 OHMS)
2
2
K1
SIGNATURE
DATE
DRAWN
DAVID CASTILLO
08/14/2006
TITLE
CHECKED
03/01/2007
ENGINEER
PRODUCTION
SIZE
CODE IDENT NO
DRAWING NO
i5
i5-9100
U SED ON
QA
SCALE
KEY
NONE
51
APPROVED
DCASTILLO
SHEET 1 OF 1