6 Specifications and regulatory information
Number of PV current inputs
Rated PV voltage
Rated current per PV input (X1/X4)
External fuse required per PV input (X1/X4)
Current measurement technology
PV input current measurement uncertainty
PV input current measurement resolution
PV input voltagemeasurement uncertainty
PV input voltage measurement resolution
Compatible DC earthing systems
Supply voltage
Supply current
Storage temperature range
Operating temperature range
Operating relative humidity range
Communications protocol
Number of digital inputs
Digital input coding
Rated impulse withstand (X1/X4, X2 and
negative copper busbars)
Applicable pollution degree
Operating altitude
Degree of protection against external
mechanical impacts (IEC 62262)
Outer dimensions (W x L x H)
Certifications
78
2008130000
Transclinic 16i+
1000 V
dc
0 – 15 A
(-25 °C ...+70 °C)
dc
≤ 20 A gPV
low-side current sensing resistors (shunts)
Typically 1%
25 mA
Typically 1%
1 V
floating, positive grounded and negative grounded
24 V
< 70 mA
steady state, 200 mA
dc
–25 °C to +70 °C
–25 °C to +70 °C
5 % to 95 %, non-condensing
Modbus RTU over RS–485 serial line
open contact "0", closed contact "1"
5.2 kV
2
≤ 3000 m
IK07 (rated energy level 2 J, tested according to clause
8.2.2 of IEC 61010-1:2010 3rd ed)
368.9 x 109.5 x 92.2 mm ±1 mm
CE mark, conformity with:
• safety:
– IEC/EN 61010–1:2010
– IEC/EN 61010–2–030:2010
• EMC (Class A equipment, industrial
electromagnetic environment):
– EN61326-1:2013
2433950000
Transclinic 16i+ 1k5
16
1500 V
dc
0 – 25 A
(-25 °C ...+60 °C)
dc
Typically 1%
30 mA
Typically 1%
1.5 V
±20 %
dc
max.
dc
2
1
≤ 2000 m
hig