Download Print this page
Weidmuller PMX420 Series Operating Instructions Manual

Weidmuller PMX420 Series Operating Instructions Manual

4-digit current/voltage display

Advertisement

Bedienungsanleitung
de
4-stellige Strom-/Spannungsanzeige
Operatinginstructions
en
4-digit current/voltage display
Moded'emploi
fr
Indicateur de courant/
tension à 4 caractères
Istruzioniperl'uso
it
Indicatore di corrente/
di tensione a 4 cifre
Instruccionesdeempleo
es
Indicador de intensidad/
tensión de 4 dígitos
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
3
16
27
40
52
PMX420-SERIE 61001099/00/01.08

Advertisement

loading

Summary of Contents for Weidmuller PMX420 Series

  • Page 1 Bedienungsanleitung 4-stellige Strom-/Spannungsanzeige Operatinginstructions 4-digit current/voltage display Moded'emploi Indicateur de courant/ tension à 4 caractères Istruzioniperl'uso Indicatore di corrente/ di tensione a 4 cifre Instruccionesdeempleo Indicador de intensidad/ tensión de 4 dígitos PMX420-SERIE 61001099/00/01.08 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 2: Table Of Contents

     PMX420SERIES Inhaltsverzeichnis Operation Installation Connections Instrument Setup Input Calibration Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 3: Operation

     PMX420SERIES Power Supply 24Vdc (Out) Analogue Output Engineering Units (PMX420 Plus Only) Current/Voltage Alarm 1 Alarm 2 (PMX420 Plus Only) Alarm 3 Alarm 4 • Operation The PMX0 is a panel mount, digit indicator for current or voltage signals. It shows the input measurement in any chosen engineering unit using bright, 1 mm high, LED digits.
  • Page 4 Maximum/Minimumrecallfunction PGM and Å recalls the minimum value for  s. PGM and ì recalls the minimum value for  s. Release the PGM key first for reliable operation. To reset either value press ENT while it is still on display. Clearingtrippedalarms You can acknowledge a tripped alarm by simply pressing the key for that channel.
  • Page 5: Installation

    • Installation Caution: In order to meet product safety requirements, these units must only be installed, by qualified staff, in accordance with the information given in this manual, using the mounting clips and terminal blocks supplied, and all relevant national electrical wiring and safety rules must be followed.
  • Page 6: Connections

    • Connections Terminal Signal Not Used Live (+) Low voltage 12-50 V AC or power supply 18-35 V DC Neutral (−) Sensor supply + / Security Link Security Link Voltage Input + Inputs Current Input + Input − / 0 V Not connected Normally Open Alarm Channel One...
  • Page 7 TypicalConnections Device with PMX420AP voltage outputs (voltage inputs) Other Device with PMX420AP receiving current outputs (current inputs) device/s 2-wire Other PMX420AP (loop powered) receiving (current inputs) Transmitter device/s Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 8: Instrument Setup

    • InstrumentSetup For setup mode, connect the security link and press PGM and ENT keys simultaneously. The software version will be displayed. If you wish to continue, press ENT within 10 s. Å ì Setting Display Description S/W Version 1.01 (Note: this information only applies to versions v1.
  • Page 9 InstrumentSetup(continued) GeneralAlarmsettings* Alarms 1 & 2 A12Y Enable Toggle Accept A12n Select Disable (Select this option for PMX420) A34Y Alarms 3 & 4 Enable Toggle Accept A34n Select Disable (Select this option for PMX420) SECy Setpoint Setpoints fixed at setup Toggle Accept SECn...
  • Page 10: Input Calibration

    InstrumentSetup(continued) dL1= Timer delay (set to 0 s to disable) Next Timer delay e.g., no delay Accept Calibrationoptions CIPn Calibrate Skip input calibration Toggle Accept CIPy Input? Calibrate inputs COPn Calibrate Skip output calibration Toggle Accept COPy Output? Calibrate outputs Instrument is saving the changes to the setup and returning to normal SAVE Save values...
  • Page 11 Procedure Whenthe Action/Description displayshows Put the instrument in setup mode and scroll through the main menu CIPn Press ì or Å CIPy Press ENT to select input calibration Connect the current source and press ENT 0. 0 0 Set the current source to 0.00 mA and press ENT Press ENT Set the current source to 20.00 mA press ENT.
  • Page 12 TerminalConnectionsforoutputcalibration CalibrationStage Signaltype Terminal mA output + Analogue Current Output mA output − V output + Analogue Voltage Output V output − Procedure Note: the procedure below shows calibration for the commonly used -0 mA format. Expect different values for other formats. Whenthe Action/Description displayshows...