1. Remove the securing screws from the electrical cover plate located on the rear left side of the appliance.
2. Loosen the securing screws from the terminal block to remove the cord from the terminal block.
3. REMOVE 2 JUMPER WIRES IN THE TERMINAL BLOCK.
4. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole from the terminal
block.
5. Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by tightening
the screws on the (N) slots.
6. Repeat step 5 with Black (L1), Red (L2) and Green (G), securing them to their designated slots in the terminal
block.
7. Re-install cover plate.
note:
Leave enough wire so that the appliance can be removed from the enclosure for ease of disconnecting the
power supply if the appliance needs to be serviced.