6.
Turn the brake knob clockwise until the brake mechanism
makes contact with the calibration tool and press the LIGHT
button.
Caution: Do not over-tighten.
7.
The console will display that the Zeropoint is now set. Press
the LIGHT button to exit CALIBRATE ZEROPOINT.
8.
Once the calibration passes, go to CALIBRATE CURRENT
ANGLE and verify the angle is 0.0 (+/- 0.1 degrees). Occa-
sionally, the calibration process does not correctly set the
angle on the fi rst try. If the angle reads anything other than
0.0 (+/- 0.1 degrees), perform the calibration again until the
CURRENT ANGLE reads 0.0 (+/- 0.1 degrees).
Note: The sensor measures in degrees, so 0.0 – 0.1 = 359.9.
9.
Exit the service menu and remove the tool from the fl y-
wheel..