Environmental site system requirements

Environmental site system requirements
The following table summarizes the environmental requirements for the normal operation of the AltaVault system:
Environmental tolerances
Operating temperature range
Altitude
Relative humidity

Controller electrical requirements

The following table summarizes the electrical requirements for an AltaVault controller module in a single controller
per chassis configuration. It shows data for a single-controller configuration with one functioning power supply
(worst-case scenario) and the typical electrical requirements with two functioning power supplies:
Specifications
Input current (Amps)
Input Power (Watts)
Thermal output (British
Thermal Unit per hour)

Configuration worksheet

Use the configuration worksheet to note any information that you require for the AltaVault deployment, including:
"Appliance information" on page 39
"Cloud provider credentials and storage configuration" on page 39
"Network connectivity" on page 40
"Advance features" on page 41
NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
Normal operating range
50 degrees F (10 degrees C) to 104degrees F (40degrees C)
0 to 10,000 feet (0 to 3,048 m)
20% to 80%, non-condensing
Number of power supply
units (PSU)
One PSU
Two PSU
One PSU
Two PSU
One PSU
Two PSU
NetApp AltaVault appliance setup preparation
100 to 120 VAC
4.55 A
3.86 A
610.06 W
488.32
2082 BTU/Hr
1666 BTU/Hr
200 to 240 VAC
2.49 A
2.33 A
577.29 W
481.13 W
1970 BTU/Hr
1642 BTU/Hr